IMPORTANT ADDENDUM/CORRECTION TO MY PREVIOUS POST ON THIS.
I wrote:
Take your ohmmeter and measure from the center, where the adjustment tool
contacts the capacitor. Measure to each of the two contacts, and find the
one that is shorted to the adjustment slot. That is the side you want to
be
The flat side on the board is indeed the grounded side - but as I
mentioned, you cannot see the flat on the silkscreen any more, you will
have to follow the diagram in the manual. The flat sides are not in the
same relative orientation - in each row of 4 there are 2 with the flat
to the left