Message-
From: elecraft-boun...@mailman.qth.net
[mailto:elecraft-boun...@mailman.qth.net] On Behalf Of Ron D'Eau Claire
Sent: Friday, May 17, 2013 10:20 PM
To: mtebe...@mchsi.com; elecraft@mailman.qth.net
Subject: Re: [Elecraft] K144XV Strange Readings
Mike: First e-mail k3supp...@elecraft.com
:59 PM
To: elecraft@mailman.qth.net
Subject: Re: [Elecraft] K144XV Strange Readings
Will someone please describe this center spacer so I can verify whether it
is in mine or not?
Was it an active part of the circuitry? If I have it in mine can I just
remove it without any other modifications? Why
I've noticed strange behavior on both the W2 watt meter and a
cross-needle meter when using my K3 on 2 meters. Just curious if anyone
has had problems like this? In SSB mode, keying the mic without any
audio causes the watt meter to show about 3 watts output power and 3:1
SWR. However If I
to finally understand what needs to be done to
correct this issues. Very common among the users that are on SSB/CW, not so
much FM.
Date: Fri, 17 May 2013 05:26:24 -0500
From: mtebe...@mchsi.com
To: Elecraft@mailman.qth.net
Subject: [Elecraft] K144XV Strange Readings
I've noticed strange
Original message
From: Chad Wasinger chadwasin...@outlook.com
Date: 05/17/2013 7:12 AM (GMT-06:00)
To: mtebe...@mchsi.com,elecraft@mailman.qth.net
Subject: RE: [Elecraft] K144XV Strange Readings
Mike - yes, I've seen the same thing. I can't put my finger on it either but
when
@mailman.qth.net
Subject: Re: [Elecraft] K144XV Strange Readings
Mike - yes, I've seen the same thing. I can't put my finger on it either but
when using the k144xv with my wattmeter, I have high SWR always. Normally I
can still run the 5-7 watts into an amp without issues but there are times
this high SWR trips
Its oscillating. Stop using it as you are transmitting outside the band -
hence the high VSWR
--
View this message in context:
http://elecraft.365791.n2.nabble.com/K144XV-Strange-Readings-tp7573719p7573742.html
Sent from the Elecraft mailing list archive at Nabble.com.
Subject: [Elecraft] K144XV Strange Readings
Message-ID: 519605d0.20...@mchsi.com
Content-Type: text/plain; charset=ISO-8859-1; format=flowed
I've noticed strange behavior on both the W2 watt meter and a
cross-needle meter when using my K3 on 2 meters. Just curious if anyone
has had problems like
!) and the issue has not
arisen since
Dave
G4FRE
Message: 19
Date: Fri, 17 May 2013 05:26:24 -0500
From: Michael Eberle mtebe...@mchsi.com
To: Elecraft@mailman.qth.net
Subject: [Elecraft] K144XV Strange Readings
Message-ID: 519605d0.20...@mchsi.com
Content-Type: text/plain; charset=ISO-8859-1
] K144XV Strange Readings
Dave,
Yes that is exactly what it appears to be doing. My frequency counter is
showing RF at 153.600 MHz regardless of what part of the band it is tuned
to. I removed the K144XV Reference Lock Board and there was no change. Is
there anything that can be done to correct
10 matches