Re: [Elecraft] K2: Strange behaviour during alignment and tests (part II)

2008-01-21 Thread David Woolley
wrote: Measuring the AGC-treashold voltage on pin 5 of U2 (control board) gives a range from 2.65-3.74 volts when adjusting R1 from counter-clockwise to This is normal, 3.8 is only achievable if all components have nominal values (and may actually not even be achievable then). It might be

[Elecraft] K2: Strange behaviour during alignment and tests (part II)

2008-01-20 Thread Hans Østnell
Hi group! I have just finished the alignments and tests (part II) in my (second) K2-project. Sofar all resistance checks are ok, and the results of the alignment and tests have also been ok. Except for one thing: I think that the AGC in the radio behaves rather strangely. It's pretty nervous in