Re: [Elecraft] K3 Fault 6 and loss of power control

2024-03-08 Thread Mike Cizek W0VTT
be the only one. --- 73, Mike Cizek WØVTT -Original Message- From: elecraft-boun...@mailman.qth.net On Behalf Of Pete Smith N4ZR Sent: Wednesday, 6 March, 2024 22:12 To: Elecraft List Subject: [Elecraft] K3 Fault 6 and loss of power control Today I started seeing this in my K3 driving

Re: [Elecraft] K3 Fault 6 and loss of power control

2024-03-07 Thread Dick Dievendorff
Check the KPA1500 fault log with the KPA1500 Utility. It’s probably fault code 60, and amp fault codes 6x are displayed on the K3 as fault 6. 7e de Dick, K6KR > On Mar 6, 2024, at 21:13, Pete Smith N4ZR wrote: > > Today I started seeing this in my K3 driving a KPA-1500. It only needs >

[Elecraft] K3 Fault 6 and loss of power control

2024-03-06 Thread Pete Smith N4ZR
Today I started seeing this in my K3 driving a KPA-1500.  It only needs around 30-34 watts to drive it to full power on CW, but when I set the K3's power to that, and everything looks fine, occasionally the K3 displays Fault 6 on its panel and causes the KPA-1500 to fault, displaying 65 watts