be the only one.
---
73,
Mike Cizek WØVTT
-Original Message-
From: elecraft-boun...@mailman.qth.net On
Behalf Of Pete Smith N4ZR
Sent: Wednesday, 6 March, 2024 22:12
To: Elecraft List
Subject: [Elecraft] K3 Fault 6 and loss of power control
Today I started seeing this in my K3 driving
Check the KPA1500 fault log with the KPA1500 Utility. It’s probably fault code
60, and amp fault codes 6x are displayed on the K3 as fault 6.
7e de Dick, K6KR
> On Mar 6, 2024, at 21:13, Pete Smith N4ZR wrote:
>
> Today I started seeing this in my K3 driving a KPA-1500. It only needs
>
Today I started seeing this in my K3 driving a KPA-1500. It only needs
around 30-34 watts to drive it to full power on CW, but when I set the
K3's power to that, and everything looks fine, occasionally the K3
displays Fault 6 on its panel and causes the KPA-1500 to fault,
displaying 65 watts
3 matches
Mail list logo