Re: [Elecraft] KAT500 Key Line Interrupt when in BYP mode?

2018-09-02 Thread Bob McGraw K4TAX
The value of SWR doesn't really inform us about the load impedance, line current or line voltage conditions existing. In the case of a 1.5:1 SWR, the load Z is 75 ohms, with a power of 500 watts the line current is 2.58 amps with a voltage of 193.6 volts. At the same time a 1.5:1 SWR, the

[Elecraft] KAT500 Key Line Interrupt when in BYP mode?

2018-09-02 Thread ANDY DURBIN
"The Elecraft KPA500 amplifier also works efficiently into a load SWR of 1.5:1" Any such claim is at best misleading. There may be some 1.5:1 loads that that the KPA500 will be happy with but there are other 1.5:1 loads that it will object to, to the point of giving multiple PA DISS faults.

Re: [Elecraft] KAT500 Key Line Interrupt when in BYP mode?

2018-09-02 Thread Michael Blake via Elecraft
Dave, yes my question was “do the VSWR Thresholds work when the KAT500 is in the Bypass mode” and the answer was No, they do not. There are workarounds of course but the question was specifically when the KAT500 had been placed in the Bypass mode with the front panel button. The manual did

Re: [Elecraft] KAT500 Key Line Interrupt when in BYP mode?

2018-09-02 Thread Barry Baines via Elecraft
Mike: > On Sep 2, 2018, at 1:27 PM, Michael Blake wrote: > > Dick from Elecraft answered my question. The short answer to my question was > “no”. > > To answer your question, yes the key line interrupt is set for 3.0:1 as it > should be. Thanks for the update and glad to hear that your

Re: [Elecraft] KAT500 Key Line Interrupt when in BYP mode?

2018-09-02 Thread Michael Blake via Elecraft
Dick from Elecraft answered my question. The short answer to my question was “no”. To answer your question, yes the key line interrupt is set for 3.0:1 as it should be. Mike - K9JRI > On Sep 2, 2018, at 13:01, Barry Baines wrote: > > Mike: > >> On Sep 2, 2018, at 11:27 AM, Michael Blake

Re: [Elecraft] KAT500 Key Line Interrupt when in BYP mode?

2018-09-02 Thread Barry Baines via Elecraft
Mike: > On Sep 2, 2018, at 11:27 AM, Michael Blake via Elecraft > wrote: > > When the KAT500 is powered on but in the Bypass mode will it still open the > key line to the KPA500 at the preset level (3.0:1 in my case) if the load > suddenly goes above 3:1? To confirm, is your SWR 3.0:1 or

[Elecraft] KAT500 Key Line Interrupt when in BYP mode?

2018-09-02 Thread Michael Blake via Elecraft
When the KAT500 is powered on but in the Bypass mode will it still open the key line to the KPA500 at the preset level (3.0:1 in my case) if the load suddenly goes above 3:1? The situation is a remote autotuner connected to a 33’ vertical that I use for bands that I do not have a resonant