Re: [Elecraft] Older K3/100s can be updated to avoid possible ERR12V problem

2012-02-14 Thread Adriano Perazio
/100s can be updated to avoid possible ERR12V problem Wayne, Define older K3 please. Can you let us know when you started shipping K3's with gold contacts; date or S/N? Thanks! Jack - WE5ST From: Wayne Burdick n...@elecraft.com To: Elecraft Reflector elecraft

Re: [Elecraft] Older K3/100s can be updated to avoid possible ERR12V problem

2012-02-14 Thread nr4c
week. After turn off it disapeared. So must be it. PY2ADR -Mensagem Original- From: Jack Berry Sent: Tuesday, February 14, 2012 2:20 PM To: Wayne Burdick ; Elecraft Reflector Cc: elecraft...@yahoogroups.com Subject: Re: [Elecraft] Older K3/100s can be updated to avoid possible

Re: [Elecraft] Older K3/100s can be updated to avoid possible ERR12V problem [more info]

2012-02-14 Thread Wayne Burdick
The change was implemented around May of 2009, meaning radios with serial numbers in the low 3000's. If you have a K3/100 more recent than this and you're seeing ERR 12 V, check the Faston terminals on the circuit breaker (they are crimped, and could be soldered or replaced). Also verify

Re: [Elecraft] Older K3/100s can be updated to avoid possible ERR12V problem

2012-02-14 Thread Stewart
To: Wayne Burdick ; Elecraft Reflector Cc: elecraft...@yahoogroups.com Subject: Re: [Elecraft] Older K3/100s can be updated to avoid possible ERR12V problem Wayne, Define older K3 please. Can you let us know when you started shipping K3's with gold contacts; date or S/N? Thanks! Jack - WE5ST

Re: [Elecraft] Older K3/100s can be updated to avoid possible ERR12V problem

2012-02-14 Thread Wayne Burdick
Both the production change and the field modification result in gold- to-gold contacts throughout the 12 V circuit to the PA. Wayne N6KR On Feb 14, 2012, at 9:12 AM, Stewart wrote: I had a look inside my K3 today. Although it is an early one, S/N 307 it has a new RF board with gold

Re: [Elecraft] Older K3/100s can be updated to avoid possible ERR12V problem

2012-02-14 Thread Adriano Perazio
that for the Hamcation visit, i donĀ“t know what will happens next. PY2ADR -Mensagem Original- From: nr4c Sent: Tuesday, February 14, 2012 2:41 PM To: elecraft@mailman.qth.net Subject: Re: [Elecraft] Older K3/100s can be updated to avoid possible ERR12V problem That's odd, as yours is newer

Re: [Elecraft] Older K3/100s can be updated to avoid possible ERR12V problem

2012-02-14 Thread Stewart
Thanks Wayne, Does the field modification also include changing pins on the KPA3 PCB, as mine are tin plated ? 73 Stewart G3RXQ On Tue, 14 Feb 2012 09:21:31 -0800, Wayne Burdick wrote: Both the production change and the field modification result in gold- to-gold contacts throughout the 12 V

Re: [Elecraft] Older K3/100s can be updated to avoid possible ERR12V problem

2012-02-14 Thread Wayne Burdick
I'm pretty sure, but check with k3support when you order the mod kit. 73, Wayne N6KR On Feb 14, 2012, at 9:35 AM, Stewart wrote: Thanks Wayne, Does the field modification also include changing pins on the KPA3 PCB, as mine are tin plated ? 73 Stewart G3RXQ On Tue, 14 Feb 2012 09:21:31

Re: [Elecraft] Older K3/100s can be updated to avoid possible ERR12V problem

2012-02-14 Thread Wayne Burdick
I was unaware of this, but I'll check with support to see what they did about it. The station may have been running extremely high duty cycle in worst-case temperature/climate conditions. We need to handle this, of course. (Nothing like extended field testing to get the engineering team