Hi all, yes D28 was in short circuit... i leave it and now the radio it's
working.. but without the Kpa100.. the same diode/zener on the Kpa100
module it's in short circuit also.
Now i have to find where to but 2 of the D28 diode...
thanks to all !!!
73 de IW0HK Andrea
On Sun, Nov 10, 2013 at
Hi,
today i was in QSO in 17 meter band CW when my power supply (switching from
Nissei model MS 280A) has shut down (i was in tx with 100 watt). After i
discover that the supply is death.. and also my K3 (#4777) now it's death
also..connected to a battery it's not swithing ON... nothing...
any
Did you confirm cable and fuses are good?
73,
Rick wa6nhc
Tiny iPhone 5 keypad, typos are inevitable
On Nov 10, 2013, at 9:17 AM, Andrea Borgnino a.borgn...@gmail.com wrote:
Hi,
today i was in QSO in 17 meter band CW when my power supply (switching from
Nissei model MS 280A) has shut down
All fuses good?
Sent from my Verizon Wireless 4G LTE DROID
Andrea Borgnino a.borgn...@gmail.com wrote:
Hi,
today i was in QSO in 17 meter band CW when my power supply (switching from
Nissei model MS 280A) has shut down (i was in tx with 100 watt). After i
discover that the supply is death..
yes cable it's good, there was no fuse on cable from K3 to the supply.
I just check the K3 with a battery and it's seem that the K3 it's in short
circuit.. the battery voltage go to 12v to 0.5v when connected to the K3..
can be the fuse inside the K3 ??
On Sun, Nov 10, 2013 at 7:19 PM, Rick
Perhaps before die, the 280A delivered an overvoltage output. That could
explain both the death of the 280A and the short of the K3.
Obviously, I hope to be wrong
Massimo I0MCF
Il 10/11/2013 20:06, Andrea Borgnino ha scritto:
yes cable it's good, there was no fuse on cable from K3