Re: [Elecraft] Broken relay in KAT2

2005-04-01 Thread Charles Greene
Tom and Don, I think the problem has cured itself. Now only the ant1 external meter reads power when ant1 is selected. Before both ant1 and ant2 were reading power when ant1 was selected. There's no indicator on ant1, just on ant2. I was mistaken about that. Tnx for the response. At

RE: [Elecraft] Broken relay in KAT2

2005-03-31 Thread W3FPR - Don Wilhelm
Chas, Look for a short between either pins 2 and 3 or pins 8 and 9 of KAT2 K18. As you have concluded, a short batween those points or a faulty relay is the only thing that could allow output on ANT 1 when ANT2 is selected. But OTOH, if the indicator says ANT 1 in all cases, that indicates a