RE: [Elecraft] Re: K2 Power Callibration

2006-02-22 Thread Don Wilhelm
John, One must be careful not to zap the diode in the RF Probe - so measuring directly across the dummy load is good only up to 20 watts or so. A 'scope with a proper probe will handle the full 100 watts of the KPA100 easily. Builders may not have a known good 'scope, and the RF Probe method

Re: [Elecraft] Re: K2 Power Callibration

2006-02-22 Thread Don Brown
- Original Message - From: Don Wilhelm [EMAIL PROTECTED] To: [EMAIL PROTECTED]; elecraft@mailman.qth.net Sent: Wednesday, February 22, 2006 6:42 PM Subject: RE: [Elecraft] Re: K2 Power Callibration John, One must be careful not to zap the diode in the RF Probe - so measuring

Re: [Elecraft] Re: K2 Power Callibration

2006-02-22 Thread Larry Phipps
- From: Don Wilhelm [EMAIL PROTECTED] To: [EMAIL PROTECTED]; elecraft@mailman.qth.net Sent: Wednesday, February 22, 2006 6:42 PM Subject: RE: [Elecraft] Re: K2 Power Callibration John, One must be careful not to zap the diode in the RF Probe - so measuring directly across the dummy load is good