I have just tried my K-3/KPA-1500 combo on 160. I find that I can only
increase the drive to 26 watts, to deliver about 880 watts input before
the OVR light comes on. Is this to be expected? Don't see anything in
the manual about it.
--
73, Pete N4ZR
The fault table should show what threshold is being exceeded. Recent 160 meter
soft fault detail would be of interest.
73 de Dick, K6KR
> On Nov 17, 2023, at 19:51, Pete Smith N4ZR wrote:
>
> I have just tried my K-3/KPA-1500 combo on 160. I find that I can only
> increase the drive to 26
Pete, I ran 1.5kw on 160 with an EFHW and did not have any issues. I ran
feedline underground and had great results. I would suspect some rf feedback.
Which can cause anomalies.
Bill
K9YEQ
From: elecraft-boun...@mailman.qth.net on
behalf of Dick Dievendorff
3 matches