Re: [Elecraft] KX3 Question on S-Meter Calibration
I thought I understood this but appears that I had it wrong. According to the SMTR calibration procedure, it is set with the PRE on and ATTN off. Calibration sets a 50uV signal to S9 and a 1uV to S2-S3. See this in the Calibration Procedures section of the manual (p51 in my 2009 version). I’ve been using the SMTR ABS mode ever since I discovered it. YMMV 73, Brian, K0DTJ > On Oct 10, 2022, at 14:05, D Remy wrote: > > Does that also apply to the K3? > > David R Hourdequin, PE > 828-421-6216 > >> On Oct 10, 2022, at 14:20, Don Wilhelm wrote: >> >> Greg, >> >> The KX3 is designed around having the preamp on most of the time. >> >> 73, >> Don W3FPR >> On 10/10/2022 1:58 PM, WA1JXR ALGIERI wrote: >>> I have noticed with my KX3 that the S-Meter is not calibrated that is 50 >>> microvolts (-73 dBm) at the antenna connector equals a S9 signal only when >>> the preamp is turned on. Is this normal and the way the KX3 is designed? >>> I thought it might be with the preamp off. >>> >>> This list hosted by: http://www.qsl.net >>> Please help support this email list: http://www.qsl.net/donate.html >>> Message delivered to d...@w3fpr.com >> >> __ >> Elecraft mailing list >> Home: http://mailman.qth.net/mailman/listinfo/elecraft >> Help: http://mailman.qth.net/mmfaq.htm >> Post: mailto:Elecraft@mailman.qth.net >> >> This list hosted by: http://www.qsl.net >> Please help support this email list: http://www.qsl.net/donate.html >> Message delivered to d...@dremy.com > > > __ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:Elecraft@mailman.qth.net > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to huntin...@coastside.net __ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to arch...@mail-archive.com
Re: [Elecraft] KX3 Question on S-Meter Calibration
Thanks! David R. Hourdequin, PE Specialty Heavy Timber and Glulam Engineering Hayesville, NC 28904 828-421-6216 > On Oct 10, 2022, at 22:14, Walter Underwood wrote: > > I’m pretty sure the K3 has an S-meter absolute mode that adjusts the S-meter > reading when preamps and/or attenuators are turned on. > > The KX3 is supposed to have that mode, but it is not implemented. From the > manual errata: > > "Not implemented: S-meter absolute mode (MENU:SMTR MD); addressing of > multiple transverters (XVn ADR)." > > https://ftp.elecraft.com/KX3/Manuals%20Downloads/E740163E%20KX3%20Owner%27s%20Manual%20Errata%20C5-3.pdf > > wunder > K6WRU > Walter Underwood > CM87wj > http://observer.wunderwood.org/ (my blog) > >> On Oct 10, 2022, at 2:04 PM, D Remy wrote: >> >> Does that also apply to the K3? >> >> David R Hourdequin, PE >> 828-421-6216 >> On Oct 10, 2022, at 14:20, Don Wilhelm wrote: >>> >>> Greg, >>> >>> The KX3 is designed around having the preamp on most of the time. >>> >>> 73, >>> Don W3FPR >>> On 10/10/2022 1:58 PM, WA1JXR ALGIERI wrote: I have noticed with my KX3 that the S-Meter is not calibrated that is 50 microvolts (-73 dBm) at the antenna connector equals a S9 signal only when the preamp is turned on. Is this normal and the way the KX3 is designed? I thought it might be with the preamp off. This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to d...@w3fpr.com >>> >>> __ >>> Elecraft mailing list >>> Home: http://mailman.qth.net/mailman/listinfo/elecraft >>> Help: http://mailman.qth.net/mmfaq.htm >>> Post: mailto:Elecraft@mailman.qth.net >>> >>> This list hosted by: http://www.qsl.net >>> Please help support this email list: http://www.qsl.net/donate.html >>> Message delivered to d...@dremy.com >> >> >> __ >> Elecraft mailing list >> Home: http://mailman.qth.net/mailman/listinfo/elecraft >> Help: http://mailman.qth.net/mmfaq.htm >> Post: mailto:Elecraft@mailman.qth.net >> >> This list hosted by: http://www.qsl.net >> Please help support this email list: http://www.qsl.net/donate.html >> Message delivered to wun...@wunderwood.org > > __ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:Elecraft@mailman.qth.net > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to d...@dremy.com __ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to arch...@mail-archive.com
Re: [Elecraft] KX3 Question on S-Meter Calibration
I’m pretty sure the K3 has an S-meter absolute mode that adjusts the S-meter reading when preamps and/or attenuators are turned on. The KX3 is supposed to have that mode, but it is not implemented. From the manual errata: "Not implemented: S-meter absolute mode (MENU:SMTR MD); addressing of multiple transverters (XVn ADR)." https://ftp.elecraft.com/KX3/Manuals%20Downloads/E740163E%20KX3%20Owner%27s%20Manual%20Errata%20C5-3.pdf wunder K6WRU Walter Underwood CM87wj http://observer.wunderwood.org/ (my blog) > On Oct 10, 2022, at 2:04 PM, D Remy wrote: > > Does that also apply to the K3? > > David R Hourdequin, PE > 828-421-6216 > >> On Oct 10, 2022, at 14:20, Don Wilhelm wrote: >> >> Greg, >> >> The KX3 is designed around having the preamp on most of the time. >> >> 73, >> Don W3FPR >> >>> On 10/10/2022 1:58 PM, WA1JXR ALGIERI wrote: >>> I have noticed with my KX3 that the S-Meter is not calibrated that is 50 >>> microvolts (-73 dBm) at the antenna connector equals a S9 signal only when >>> the preamp is turned on. Is this normal and the way the KX3 is designed? >>> I thought it might be with the preamp off. >>> >>> This list hosted by: http://www.qsl.net >>> Please help support this email list: http://www.qsl.net/donate.html >>> Message delivered to d...@w3fpr.com >> >> __ >> Elecraft mailing list >> Home: http://mailman.qth.net/mailman/listinfo/elecraft >> Help: http://mailman.qth.net/mmfaq.htm >> Post: mailto:Elecraft@mailman.qth.net >> >> This list hosted by: http://www.qsl.net >> Please help support this email list: http://www.qsl.net/donate.html >> Message delivered to d...@dremy.com > > > __ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:Elecraft@mailman.qth.net > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to wun...@wunderwood.org __ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to arch...@mail-archive.com
Re: [Elecraft] KX3 Question on S-Meter Calibration
Does that also apply to the K3? David R Hourdequin, PE 828-421-6216 > On Oct 10, 2022, at 14:20, Don Wilhelm wrote: > > Greg, > > The KX3 is designed around having the preamp on most of the time. > > 73, > Don W3FPR > >> On 10/10/2022 1:58 PM, WA1JXR ALGIERI wrote: >> I have noticed with my KX3 that the S-Meter is not calibrated that is 50 >> microvolts (-73 dBm) at the antenna connector equals a S9 signal only when >> the preamp is turned on. Is this normal and the way the KX3 is designed? >> I thought it might be with the preamp off. >> >> This list hosted by: http://www.qsl.net >> Please help support this email list: http://www.qsl.net/donate.html >> Message delivered to d...@w3fpr.com > > __ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:Elecraft@mailman.qth.net > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to d...@dremy.com __ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to arch...@mail-archive.com
Re: [Elecraft] KX3 Question on S-Meter Calibration
Greg, The KX3 is designed around having the preamp on most of the time. 73, Don W3FPR On 10/10/2022 1:58 PM, WA1JXR ALGIERI wrote: I have noticed with my KX3 that the S-Meter is not calibrated that is 50 microvolts (-73 dBm) at the antenna connector equals a S9 signal only when the preamp is turned on. Is this normal and the way the KX3 is designed? I thought it might be with the preamp off. This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to d...@w3fpr.com __ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to arch...@mail-archive.com
[Elecraft] KX3 Question on S-Meter Calibration
I have noticed with my KX3 that the S-Meter is not calibrated that is 50 microvolts (-73 dBm) at the antenna connector equals a S9 signal only when the preamp is turned on. Is this normal and the way the KX3 is designed? I thought it might be with the preamp off. Greg WA1JXR __ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to arch...@mail-archive.com