Re: [Elecraft] K2 SSB crystal filter set lacks calibration value

2018-04-06 Thread Don Wilhelm

Mark,

The SSB reception will work, but the passband may not be positioned 
optimally.
Same goes for the CW filters, they will work but may not be centered at 
your desired sidetone pitch.


The audio Spectrum analyzer is easy to obtain.  Go to my website 
www.w3fpr.com and scroll down on the opening page.  You will see links 
to both version 5.17 and version 16 of Spectrogram (both freeware).

SpectrumLab also has a nice audio spectrum analyzer (free).

You may be able to get by with using broadband antenna noise from a 
"dead band" instead of a broadband noise generator, although the noise 
generator will be more convenient.  Just make certain there are no 
signals on the band you use.


You can find Spectrogram plots of what you should be looking for at 
http://www.mmccs.com/mmarc/n0ss/index_k2.html.  Scroll down to find the 
K2 Xtal Filter Alignment article - do not use the Spectrogram link on 
that website (it is no longer good), Download Spectrogram from my website.


73,
Don W3FPR

On 4/6/2018 11:32 PM, Mark Petrovic wrote:
Thanks, Don.  If I lack the spectrum analyzer and noise generator to 
perform the refinement, what sorts of outcomes can I expect?  Will the 
SSB option work, but sub-optimally?


On Fri, Apr 6, 2018 at 8:03 PM, Don Wilhelm > wrote:


Mark,

Assume it is 3.6 for the initial filter alignment.
That can be refined later. if you use an audio spectrum analyzer
and a broadband noise generator to properly position the filter
passband.

73,
Don W3FPR


On 4/6/2018 10:13 PM, Mark Petrovic wrote:

Hi.

My K2 SSB option inventory correctly has the part number
E850006 qty. 7
4.9MHz crystal filters, but the envelope containing the
filters has no
calibration value recorded on the outside.  Is there an easy
way to
determine what this value should be?




--
Mark


__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com

Re: [Elecraft] K2 SSB crystal filter set lacks calibration value

2018-04-06 Thread Mark Petrovic
Thanks, Don.  If I lack the spectrum analyzer and noise generator to
perform the refinement, what sorts of outcomes can I expect?  Will the SSB
option work, but sub-optimally?

On Fri, Apr 6, 2018 at 8:03 PM, Don Wilhelm  wrote:

> Mark,
>
> Assume it is 3.6 for the initial filter alignment.
> That can be refined later. if you use an audio spectrum analyzer and a
> broadband noise generator to properly position the filter passband.
>
> 73,
> Don W3FPR
>
>
> On 4/6/2018 10:13 PM, Mark Petrovic wrote:
>
>> Hi.
>>
>> My K2 SSB option inventory correctly has the part number E850006 qty. 7
>> 4.9MHz crystal filters, but the envelope containing the filters has no
>> calibration value recorded on the outside.  Is there an easy way to
>> determine what this value should be?
>>
>


-- 
Mark
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com


Re: [Elecraft] K2 SSB crystal filter set lacks calibration value

2018-04-06 Thread Don Wilhelm

Mark,

Assume it is 3.6 for the initial filter alignment.
That can be refined later. if you use an audio spectrum analyzer and a 
broadband noise generator to properly position the filter passband.


73,
Don W3FPR

On 4/6/2018 10:13 PM, Mark Petrovic wrote:

Hi.

My K2 SSB option inventory correctly has the part number E850006 qty. 7
4.9MHz crystal filters, but the envelope containing the filters has no
calibration value recorded on the outside.  Is there an easy way to
determine what this value should be?

__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com


[Elecraft] K2 SSB crystal filter set lacks calibration value

2018-04-06 Thread Mark Petrovic
Hi.

My K2 SSB option inventory correctly has the part number E850006 qty. 7
4.9MHz crystal filters, but the envelope containing the filters has no
calibration value recorded on the outside.  Is there an easy way to
determine what this value should be?

Thanks.

-- 
Mark
AE6RT
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com