Re: [O] Bug: Clock times not summed correctly between years [9.0.9 (9.0.9-82-gb862c2-elpa @ ~/.emacs.d/elpa/org/)]

2018-01-07 Thread Paul Stansell
I see that the exact same "bug" was reported at the start of 2016 by David Bremner. Personally, I feel that fewer people would be confused by this if the default value was set to "untilnow". I also realised that the full list of values that I can use for org-clock-display-default-range is describ

Re: [O] Bug: Clock times not summed correctly between years [9.0.9 (9.0.9-82-gb862c2-elpa @ ~/.emacs.d/elpa/org/)]

2018-01-06 Thread Nicolas Goaziou
Paul Stansell writes: > Thanks for that tip, I was totally unaware of that option (it doesn't seem > to be mentioned in the user documentation, eg, it's not mentioned on > https://orgmode.org/manual/Clocking-commands.html). I added a reference to that variable in Org 8.2 manual. Thank you for th

Re: [O] Bug: Clock times not summed correctly between years [9.0.9 (9.0.9-82-gb862c2-elpa @ ~/.emacs.d/elpa/org/)]

2018-01-06 Thread Samuel Wales
default should perhaps be changed? On 1/6/18, Paul Stansell wrote: > I do wonder why the default range should be set at the current year and not > simply over the full range of clocked times in a heading.

Re: [O] Bug: Clock times not summed correctly between years [9.0.9 (9.0.9-82-gb862c2-elpa @ ~/.emacs.d/elpa/org/)]

2018-01-06 Thread Paul Stansell
Hello Nicolas, Thanks for that tip, I was totally unaware of that option (it doesn't seem to be mentioned in the user documentation, eg, it's not mentioned on https://orgmode.org/manual/Clocking-commands.html). I do wonder why the default range should be set at the current year and not simply ove

Re: [O] Bug: Clock times not summed correctly between years [9.0.9 (9.0.9-82-gb862c2-elpa @ ~/.emacs.d/elpa/org/)]

2018-01-06 Thread Nicolas Goaziou
Hello, Paul Stansell writes: > The sum of the clock time seems to be summing just times in the current > year. In the example below typing C-c C-x C-d in the "Example" section > displays "1:00" instead of "2:00" on the heading line. The clocktable > computes the sum correctly as "2:00". See `

[O] Bug: Clock times not summed correctly between years [9.0.9 (9.0.9-82-gb862c2-elpa @ ~/.emacs.d/elpa/org/)]

2018-01-06 Thread Paul Stansell
Hello, The sum of the clock time seems to be summing just times in the current year. In the example below typing C-c C-x C-d in the "Example" section displays "1:00" instead of "2:00" on the heading line. The clocktable computes the sum correctly as "2:00". Thanks # Start Example -