RMCEMC Society March Meeting

2001-03-19 Thread ChasGrasso
To all interested parties, The RMCEMC will be hosting W.Scott Bennett who will present : THE BASIC PHYSICS OF ELECTROMAGNETICS WITHOUT ABSTRACT MATHEMATICS List-Post: emc-pstc@listserv.ieee.org Date: March 21st Time: 1:00pm - 4:00pm For full details please goto our website at

Recall: Do not dial 9, 0, #, then hang up when requested.

2001-03-19 Thread Spadaccini, Fabian
Spadaccini, Fabian would like to recall the message, Do not dial 9, 0, #, then hang up when requested..

RE: Do not dial 9, 0, #, then hang up when requested.

2001-03-19 Thread Larry Merchell
I just verified this warning as valid with my local phone service (COX Cable). Larry Merchell Design Engineer Taiyo Yuden (USA) Inc. 1770 La Costa Meadows Drive San Marcos, Ca 92069 Tel: 760-510-3200 Fax: 760-471-4022 E-Mail: lmerch...@t-yuden.com Web: www.T-Yuden.com -Original

RE: Do not dial 9, 0, #, then hang up when requested.

2001-03-19 Thread Spadaccini, Fabian
http://www.att.com/features/0398/90pound.html This link confirms Jacob's suspicions! Regards, Fabian Spadaccini TA Instruments-Waters LLC (p) 302-427-4189 (f) 302-427-4081 fspadacc...@tainst.com www.tainst.com -Original Message- From: Jacob Schanker

Re: Do not dial 9, 0, #, then hang up when requested.

2001-03-19 Thread Ted . Eckert
This warning is basically a hoax. 90# has no affect on home telephones and it only affects some older PBX systems. Full information can be found at: http://hoaxbusters.ciac.org/HBInconsequential.shtml#90phone If you receive E-mail that has some type of warning in it, check the Hoaxbusters

RE: Do not dial 9, 0, #, then hang up when requested.

2001-03-19 Thread Hare, Paul
The whole truth http://www.truthorfiction.com/rumors/ninezeropound.htm Paul Hare e: ph...@pirus.com Compliance Engineer w: 978.206.9179 Pirus Networks f: 978.206.9199 43 Nagog Park c: 508.450.0376 Acton, MA 01720 i: www.pirus.com -Original

RE: Non-NRTL Test Reports

2001-03-19 Thread Gary McInturff
These tests are used for both inclusion and exclusion. If you are the only source you may have a chance, if you're not or if they have a preference of some sort, your risk of loosing the sale to a competitor is greatly increased. You still have the option of having a NRTL witness

Re: Do not dial 9, 0, #, then hang up when requested.

2001-03-19 Thread Jacob Schanker
All: This sounds like another UL. That's UL as in Urban Legend. Just picture GTE telling someone that they should tell EVERYONE they know. NOT going to happen. Before we flood emc-pstc and the Internet with this urgent warning - think about it first. Regards, Jack Jacob Z. Schanker, P.E. 65

Re: Do not dial 9, 0, #, then hang up when requested.

2001-03-19 Thread Lou Aiken
This does NOT happen when I try it between my two separate phone lines. Rgds. Lou Lou Aiken 27109 Palmetto Drive Orange Beach, AL 36561 U.S.A. tel1-334-981-6786 fax 1-334-981-3054 mobile 1-334-979-4648 - Original Message - From: david_l_tarnow...@email.whirlpool.com To:

[Fwd: FW: Field trial requirements]

2001-03-19 Thread David Heald
Forwarded for Joel Mandel. Please select reply all when responding or include Joel in your CC line joel_man...@adc.com. Dave Heald -Original Message- From: Mandel, Joel Sent: á îøõ 19 2001 10:33 To: 'emc-p...@ieee.org' Subject: Field trial requirements Hi All Does

Do not dial 9, 0, #, then hang up when requested.

2001-03-19 Thread David_L_Tarnowski
__ Forward Header __ Subject: Do not dial 9, 0, #, then hang up when requested. Author: cfil...@sears.com at INTERNET List-Post: emc-pstc@listserv.ieee.org Date:3/19/2001 7:44 AM PLEASE READ THE FOLLOWING WARNING FROM IRV

Non-NRTL Test Reports

2001-03-19 Thread Tudor, Allen
Greetings, I'm trying to get a feel for how well the Regional Bell Operating Companies (RBOC's) have accepted non-NRTL test reports for GR-1089, especially for sections 2 and 3 (ESD and EMI). From what I understand, the requirement for NRTL-generated test reports has been relaxed within the

RE: Is 61000-3-2 compulsory?

2001-03-19 Thread George, David L
Jon: 150 watts under the old revisions was borderline compliance without and PFC. The old requirements were either not applicable to some products or they were for home use. Home us was and still is a flat line. The limits for home products are the same for 75 watts (300ma) as for 16 amperes.

USA EMC requirements

2001-03-19 Thread Enci
Where can I find, or what are the USA EMC requirements for conducted and radiated emissions for an independant lighting ballast for discharge lamps? Thanks in advance. Enci --- This message is from the IEEE EMC Society Product Safety Technical

Looking for alumni

2001-03-19 Thread Douglas C. Smith
Hi All, Not sure if this the right place to inquire about this, but here goes... I make electronic updates of my course notes available at no charge to people who have been students at one of my seminars. I have a good list of those that have attended my public seminars but my list from private

Re: Korean immunity requirements

2001-03-19 Thread Martin Garwood
Joe, We recently posted full details of South Korea's requirements in comparison to the EU inc test levels etc. You can see the tables and details at http://www.approvalspecialists.com/news.html#koreanemc Best, Martin. - Original Message - From: j...@aol.com To: