John, I am not familiar with IEC61000-4-10/12, but when you star talking abuot oscillatory wave testing, then I'm thinking about MIL-STD 461D. Check this one, may be it helps. http://www.solar-emc.com/pdf/9354-1.pdf Cheers. Amund -Opprinnelig melding- Fra: owner-emc-p...@majordomo.

RE: Measurement Consistency of OATS

2002-07-05 Thread Barker, Neil
I suggest that you refer to CISPR16 Clause 16. That specifies an OATS and its acceptability criteria fully. Best regards, Neil R. Barker Compliance Engineering Manager Marconi Applied Technologies Ltd. 106 Waterhouse Lane Chelmsford Essex CM1 2QU U.K. Tel: +44 (01245) 453616 Fax: +44 (01245) 453

Damped Oscillatory wave testing

2002-07-05 Thread John Cronin
Hi I am interested in purchasing gear to perform oscillatory wave testing to IEC 61000-4-10 and 61000-4-12.  Can anyone in the group recommend a source of equipment? Alternatively if anyone has any info on how to perform these tests on a pre compliance basis I would be interested in finding out h

Measurement Consistency of OATS

2002-07-05 Thread Aschenberg, Mat
Hello, Have any of you seen a paper written on the measurement consistency of an OATS? If I were to have a product repeatedly measured at an OATS, how close should I expect the measurements to be? For sake of this example, there are no cables. All measurements are performed at the same OATS. Th