I have been looking at overload protection requirements for machinery, and I am
a little unsure about application of branch protection versus supplementary
protection. For example, suppose a machine is powered from AC mains (single
phase or 3-phase, I don't think it matters). The power entry
Hi Jim,
My comments below are focused on the USA.
Will the machine be NRTL Listed as a whole? If not, then branch circuit
rated devices will be required in the end installation. If so, then it will
be the judgment of the NRTL that does the Listing evaluation. I would
expect that they may require