Hello Cyril, CISPR 22/A1 address Subclause 10.4: Equipment set-up, Table top equipment: Main cable and cables connected to remote peripheral shall be fitted with ferrite clamps or tupes where the cable reaches the floor. Insertion loss > 15 dB from 30 to 1000 MHz when measured in a 50 ohm system. This amendmend is expected to make measurement easier to reproduce. Best regards
Helge Knudsen EMC Department DELTA Electronics Testing, EMC Venlighedsvej 4, DK-2970 Hoersholm Telephone : +45 45 86 77 22 Fax : +45 45 86 58 98 Email : h...@delta.dk ---------- From: Binnom, Cyril A[SMTP:binno...@ems-t.com] Reply To: Binnom, Cyril A Sent: tirsdag, oktober 24, 2000 15:02 To: emc-pstc Subject: CISPR 22 am1 2000 Group, Is anybody aware of this new amendment, that could offer me a brief detail of what it entails. Any help will be appreciated. Cyril A. Binnom Jr. EMI/EMC Approvals Engineer LXE, Inc. (770) 447-4224 Ext. 3240 (770) 447-6928 Fax Visit Our Website at: http://www.lxe.com ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: majord...@ieee.org with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: jim_bac...@mail.monarch.com Michael Garretson: pstc_ad...@garretson.org For policy questions, send mail to: Richard Nute: ri...@ieee.org ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: majord...@ieee.org with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: jim_bac...@mail.monarch.com Michael Garretson: pstc_ad...@garretson.org For policy questions, send mail to: Richard Nute: ri...@ieee.org