RE: EN 61000-4-6 CDNs for a high speed bus.

2000-08-02 Thread UMBDENSTOCK
: emc-p...@ieee.org Subject: Re: EN 61000-4-6 CDNs for a high speed bus. Don, If no CDN networks are suitable - and indeed they are not for high communication lines -, you should consider the possibility to use the EM-clamp as described in EN61000-4-6. That's the way we perform tests

Re: EN 61000-4-6 CDNs for a high speed bus.

2000-08-02 Thread Chris Collin
Don, If no CDN networks are suitable - and indeed they are not for high communication lines -, you should consider the possibility to use the EM-clamp as described in EN61000-4-6. That's the way we perform tests without degradation of the EUT signals. Regards, Chris On Tue, 01 August 2000,