RE: ISO TR 10605 test setup (ESD)

2001-06-19 Thread Mike Hopkins
measured significant potentials between separate grounds in the same building.. Mike Hopkins KeyTek -Original Message- From: Chris Maxwell [mailto:chris.maxw...@nettest.com] Sent: Tuesday, June 19, 2001 8:46 AM To: 'Chris Chileshe'; emc-p...@majordomo.ieee.org Subject: RE: ISO TR 10605

Re: ISO TR 10605 test setup (ESD)

2001-06-19 Thread John Woodgate
83d652574e7af740873674f9fc12dbaa675...@utexh1w2.gnnettest.com, Chris Maxwell chris.maxw...@nettest.com inimitably wrote: The GRP's connection to Earth ground serves two purposes. It is a low frequency ground connection to ensure that, over time, the GRP's DC potential won't change with respect

RE: ISO TR 10605 test setup (ESD)

2001-06-19 Thread Chris Maxwell
Hi from one Chris to another, I'm going to address your ground rod concerns (Question 3). In our lab here, we have a new building with new wiring and a reliable third wire Earth ground, so I simply tie my Ground Reference Plane (GRP) to the third wire of one of the AC outlets in the room. I