lto:p.perk...@ieee.org> p.perk...@ieee.org
Entropy ain’t what it used to be
From: Joe Randolph
Sent: Thursday, September 5, 2019 11:21 PM
To: EMC-PSTC@LISTSERV.IEEE.ORG
Subject: Re: [PSES] Applicable safety standard ITE equipment used on a factory
floor?
Ken, John, Charlie:
Thanks for
> j...@randolph-telecom.com
<http://www.randolph-telecom.com/> http://www.randolph-telecom.com
From: IBM Ken [mailto:ibm...@gmail.com]
Sent: Thursday, September 5, 2019 8:56 AM
To: EMC-PSTC@LISTSERV.IEEE.ORG
Subject: Re: [PSES] Applicable safety standard ITE equipment used on a fa
Hi Joe!
60950-1 is the standard for Safety of Information Technology Equipment, but
the presumption of conformity of this standard is going away in the EU
relatively soon. It will be replaced by 62368-1, which is a standard that
combines the product scopes of information technology equipment and
a
60950-1 is on the way out very soon and is replaced by 62368-1, which is
VERY different and should certainly be used for all new products.
Best wishes
John Woodgate OOO-Own Opinions Only
J M Woodgate and Associates www.woodjohn.uk
Rayleigh, Essex UK
On 2019-09-05 01:22, Joe Randolph wrote:
He
Hello All:
I have been asked whether IEC 60950-1 and IEC 62368-1 are appropriate safety
standards for a "box" that resides on a factory floor and provides internet
access to a variety of sensors distributed throughout the factory floor.
Are there other safety standards that are specific to
5 matches