Re: [PSES] Fire enclosure IEC/EN61010 - flammability classification

2019-12-09 Thread Richard Nute
Hi Amund: Yes. See IEC 61010-1 2010, 9.3.2 c) 2). Best regards, Rich From: Amund Westin Sent: Monday, December 9, 2019 3:46 AM To: EMC-PSTC@LISTSERV.IEEE.ORG Subject: [PSES] Fire enclosure IEC/EN61010 - flammability classification * Moveable equipment (4 pcs

Re: [PSES] Fire enclosure IEC/EN61010 - flammability classification

2019-12-09 Thread Brian Kunde
The actual requirement is "2) The ENCLOSURE, and any baffle or flame barrier, shall be made of metal (except magnesium) or of non-metallic materials having a flammability classification of *V-1 or better*, of IEC 60695- 11-10." Keep in mind the "or better". Most enclosures I have ever seen are

[PSES] Fire enclosure IEC/EN61010 - flammability classification

2019-12-09 Thread Amund Westin
* Moveable equipment (4 pcs castor wheels). * * Contains various electronics (230VAC, EN60950 power supplies, low power PCBs, etc) * Bottom plate of metal. Enclosure: sides and top of plastic material, type V-1, correct? Best regards Amund -