[PSES] [EXTERNAL] Re: [PSES] IEC 62368-1 ES3/PS3 cold impact test temperature

2022-10-27 Thread Chris
 Thank you Ryan Jazz and John Woodgate.
Christopher



On Thursday, October 27, 2022 at 02:02:32 PM PDT, Ryan Jazz 
 wrote: 
Hello Chris,
 
“…the test is carried out at ambient temperature equal to the minimum ambient 
temperature specified by the manufacturer or -33°C if no minimum ambient 
temperature is specified, for 24 h.”
 
  
 
Ryan Jayasinghe
 
Regulatory Compliance Engineer
 
rjayasin...@line6.com
 
  
 
"After silence, that which best expresses the inexpressible, is music" - Aldous 
Huxley
 
LINE6
 
26580 Agoura Road
 
Calabasas CA 91302
 
818.575.3711
 
line6.com
 
ampeg.com
 
From: Chris <0133def26cf0-dmarc-requ...@listserv.ieee.org>
Sent: Wednesday, October 26, 2022 8:56 AM
To: EMC-PSTC@LISTSERV.IEEE.ORG
Subject: [EXTERNAL] Re: [PSES] IEC 62368-1 ES3/PS3 cold impact test temperature
 
  
 
|  | 
You don't often get email 
from0133def26cf0-dmarc-requ...@listserv.ieee.org.Learn why this is important
  |  |


Thanks Don.
 
  
 
Do you know at what temperature is the cold impact test done?
 
  
 
Christopher
 
  
 
  
 
On Friday, October 21, 2022 at 05:04:33 AM PDT, Don Gies  
wrote:

Christopher,
 
Per Annex Y.6, you have to consider performing the cold impact tests on 
polymeric outdoor enclosures housing class 3 energy sources.
 
Best regards,

| 
Don Gies
  |

 
  
 
 
 
Folks,
 
 
 
When do we need to do IEC 62368-1 ES3/PS3 cold impact test as per IEC 62368-1 
Third edition.
 
 
 
I was told if EUT is powered by ES3/PS3 then it is required.
 
 
 
any insight will be helpful
 
 
 
Thanks in advance
 
 
 
Christopher
  

-

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 


All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Mike Cantwell 

For policy questions, send mail to:
Jim Bacher:  
David Heald: 
_
To unsubscribe from the EMC-PSTC list, click the following link: 
https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC=1

Re: [PSES] [EXTERNAL] Re: [PSES] IEC 62368-1 ES3/PS3 cold impact test temperature

2022-10-27 Thread Ryan Jazz
Hello Chris,
“…the test is carried out at ambient temperature equal to the minimum ambient 
temperature specified by the manufacturer or -33°C if no minimum ambient 
temperature is specified, for 24 h.”

Ryan Jayasinghe
Regulatory Compliance Engineer
rjayasin...@line6.com<mailto:rjayasin...@line6.com>

"After silence, that which best expresses the inexpressible, is music" - Aldous 
Huxley

LINE6
26580 Agoura Road
Calabasas CA 91302
818.575.3711
line6.com
ampeg.com

From: Chris <0133def26cf0-dmarc-requ...@listserv.ieee.org>
Sent: Wednesday, October 26, 2022 8:56 AM
To: EMC-PSTC@LISTSERV.IEEE.ORG
Subject: [EXTERNAL] Re: [PSES] IEC 62368-1 ES3/PS3 cold impact test temperature

You don't often get email from 
0133def26cf0-dmarc-requ...@listserv.ieee.org<mailto:0133def26cf0-dmarc-requ...@listserv.ieee.org>.
 Learn why this is important<https://aka.ms/LearnAboutSenderIdentification>
Thanks Don.

Do you know at what temperature is the cold impact test done?

Christopher


On Friday, October 21, 2022 at 05:04:33 AM PDT, Don Gies 
mailto:donald.g...@se.com>> wrote:



Christopher,



Per Annex Y.6, you have to consider performing the cold impact tests on 
polymeric outdoor enclosures housing class 3 energy sources.



Best regards,



Don Gies











Folks,



When do we need to do IEC 62368-1 ES3/PS3 cold impact test as per IEC 62368-1 
Third edition.



I was told if EUT is powered by ES3/PS3 then it is required.



any insight will be helpful



Thanks in advance



Christopher




-


This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
mailto:emc-p...@ieee.org>>

All emc-pstc postings are archived and searchable on the web at: 
http://www.ieee-pses.org/emc-pstc.html

Website: http://www.ieee-pses.org/
Instructions: http://www.ieee-pses.org/list.html (including how to 
unsubscribe)<http://www.ieee-pses.org/list.html>
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Mike Cantwell mailto:mcantw...@ieee.org>>

For policy questions, send mail to:
Jim Bacher mailto:j.bac...@ieee.org>>
David Heald mailto:dhe...@gmail.com>>



To unsubscribe from the EMC-PSTC list, click the following link: 
https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC=1

-

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 


All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Mike Cantwell 

For policy questions, send mail to:
Jim Bacher:  
David Heald: 
_
To unsubscribe from the EMC-PSTC list, click the following link: 
https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC=1


Re: [PSES] IEC 62368-1 ES3/PS3 cold impact test temperature

2022-10-26 Thread Chris
 Thanks Don.
Do you know at what temperature is the cold impact test done?
Christopher

On Friday, October 21, 2022 at 05:04:33 AM PDT, Don Gies 
 wrote:  
 
 
Christopher,
 
  
 
Per Annex Y.6, you have to consider performing the cold impact tests on 
polymeric outdoor enclosures housing class 3 energy sources.
 
  
 
Best regards,
 
  
 
| 
Don Gies
  |


  
 
  
 


 
 
 
Folks,
 
  
 
When do we need to do IEC 62368-1 ES3/PS3 cold impact test as per IEC 62368-1 
Third edition.
 
  
 
I was told if EUT is powered by ES3/PS3 then it is required.
 
  
 
any insight will be helpful
 
  
 
Thanks in advance
 
  
 
Christopher
 
  
 


   

-

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 


All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Mike Cantwell 

For policy questions, send mail to:
Jim Bacher:  
David Heald: 
_
To unsubscribe from the EMC-PSTC list, click the following link: 
https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC=1

Re: [PSES] IEC 62368-1 ES3/PS3 cold impact test

2022-10-23 Thread Boštjan Glavič
Hi Christopher,

This is applicable for outdoor product. IP test follows cold impact test.

Best regards,
Boštjan



From: Don Gies <0e5e843b011c-dmarc-requ...@listserv.ieee.org>
Sent: Friday, October 21, 2022 2:04 PM
To: EMC-PSTC@LISTSERV.IEEE.ORG
Subject: Re: [PSES] IEC 62368-1 ES3/PS3 cold impact test

CAUTION: This email originated from outside of our organisation. Do not click 
links or open attachments unless you recognise the sender and know the content 
is safe.

Christopher,

Per Annex Y.6, you have to consider performing the cold impact tests on 
polymeric outdoor enclosures housing class 3 energy sources.

Best regards,

Don Gies



Internal
From: Chris 
<0133def26cf0-dmarc-requ...@listserv.ieee.org<mailto:0133def26cf0-dmarc-requ...@listserv.ieee.org>>
Sent: Thursday, October 20, 2022 5:43 PM
To: EMC-PSTC@LISTSERV.IEEE.ORG<mailto:EMC-PSTC@LISTSERV.IEEE.ORG>
Subject: [PSES] IEC 62368-1 ES3/PS3 cold impact test


[External email: Use caution with links and attachments]




Folks,

When do we need to do IEC 62368-1 ES3/PS3 cold impact test as per IEC 62368-1 
Third edition.

I was told if EUT is powered by ES3/PS3 then it is required.

any insight will be helpful

Thanks in advance

Christopher

-


This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
mailto:emc-p...@ieee.org>>

All emc-pstc postings are archived and searchable on the web at: 
http://www.ieee-pses.org/emc-pstc.html<https://eur02.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.ieee-pses.org%2Femc-pstc.html=05%7C01%7Cdonald.gies%40se.com%7C91fb203f016b4a7b14d808dab2e41970%7C6e51e1adc54b4b39b5980ffe9ae68fef%7C0%7C0%7C638018989994406040%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000%7C%7C%7C=3fR86FvR9FnFrydfJuBOHT5UaZmIJqXaO36RWYT2TmY%3D=0>

Website: 
http://www.ieee-pses.org/<https://eur02.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.ieee-pses.org%2F=05%7C01%7Cdonald.gies%40se.com%7C91fb203f016b4a7b14d808dab2e41970%7C6e51e1adc54b4b39b5980ffe9ae68fef%7C0%7C0%7C638018989994406040%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000%7C%7C%7C=XZQ9lyNiEjqPUOw9Ozv7bvxzsGrc6vHtIrIBubfYro0%3D=0>
Instructions: http://www.ieee-pses.org/list.html (including how to 
unsubscribe)<https://eur02.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.ieee-pses.org%2Flist.html=05%7C01%7Cdonald.gies%40se.com%7C91fb203f016b4a7b14d808dab2e41970%7C6e51e1adc54b4b39b5980ffe9ae68fef%7C0%7C0%7C638018989994406040%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000%7C%7C%7C=4t2biSBxpuD4Y1aVZUtUhfO4cRlFRG20aIGUTQ0Eov0%3D=0>
List rules: 
http://www.ieee-pses.org/listrules.html<https://eur02.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.ieee-pses.org%2Flistrules.html=05%7C01%7Cdonald.gies%40se.com%7C91fb203f016b4a7b14d808dab2e41970%7C6e51e1adc54b4b39b5980ffe9ae68fef%7C0%7C0%7C638018989994406040%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000%7C%7C%7C=rwlwUMrfqCmun1L3fefsBkOLZFbdTFs9tG886n90fFE%3D=0>

For help, send mail to the list administrators:
Mike Cantwell mailto:mcantw...@ieee.org>>

For policy questions, send mail to:
Jim Bacher mailto:j.bac...@ieee.org>>
David Heald mailto:dhe...@gmail.com>>



To unsubscribe from the EMC-PSTC list, click the following link: 
https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC=1
-


This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
mailto:emc-p...@ieee.org>>

All emc-pstc postings are archived and searchable on the web at: 
http://www.ieee-pses.org/emc-pstc.html

Website: http://www.ieee-pses.org/
Instructions: http://www.ieee-pses.org/list.html (including how to 
unsubscribe)<http://www.ieee-pses.org/list.html>
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Mike Cantwell mailto:mcantw...@ieee.org>>

For policy questions, send mail to:
Jim Bacher mailto:j.bac...@ieee.org>>
David Heald mailto:dhe...@gmail.com>>



To unsubscribe from the EMC-PSTC list, click the following link: 
https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC=1

-

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 


All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.

Re: [PSES] IEC 62368-1 ES3/PS3 cold impact test

2022-10-21 Thread Don Gies
Christopher,

Per Annex Y.6, you have to consider performing the cold impact tests on 
polymeric outdoor enclosures housing class 3 energy sources.

Best regards,

Don Gies



Internal
From: Chris <0133def26cf0-dmarc-requ...@listserv.ieee.org>
Sent: Thursday, October 20, 2022 5:43 PM
To: EMC-PSTC@LISTSERV.IEEE.ORG
Subject: [PSES] IEC 62368-1 ES3/PS3 cold impact test


[External email: Use caution with links and attachments]




Folks,

When do we need to do IEC 62368-1 ES3/PS3 cold impact test as per IEC 62368-1 
Third edition.

I was told if EUT is powered by ES3/PS3 then it is required.

any insight will be helpful

Thanks in advance

Christopher

-


This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
mailto:emc-p...@ieee.org>>

All emc-pstc postings are archived and searchable on the web at: 
http://www.ieee-pses.org/emc-pstc.html<https://eur02.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.ieee-pses.org%2Femc-pstc.html=05%7C01%7Cdonald.gies%40se.com%7C91fb203f016b4a7b14d808dab2e41970%7C6e51e1adc54b4b39b5980ffe9ae68fef%7C0%7C0%7C638018989994406040%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000%7C%7C%7C=3fR86FvR9FnFrydfJuBOHT5UaZmIJqXaO36RWYT2TmY%3D=0>

Website: 
http://www.ieee-pses.org/<https://eur02.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.ieee-pses.org%2F=05%7C01%7Cdonald.gies%40se.com%7C91fb203f016b4a7b14d808dab2e41970%7C6e51e1adc54b4b39b5980ffe9ae68fef%7C0%7C0%7C638018989994406040%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000%7C%7C%7C=XZQ9lyNiEjqPUOw9Ozv7bvxzsGrc6vHtIrIBubfYro0%3D=0>
Instructions: http://www.ieee-pses.org/list.html (including how to 
unsubscribe)<https://eur02.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.ieee-pses.org%2Flist.html=05%7C01%7Cdonald.gies%40se.com%7C91fb203f016b4a7b14d808dab2e41970%7C6e51e1adc54b4b39b5980ffe9ae68fef%7C0%7C0%7C638018989994406040%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000%7C%7C%7C=4t2biSBxpuD4Y1aVZUtUhfO4cRlFRG20aIGUTQ0Eov0%3D=0>
List rules: 
http://www.ieee-pses.org/listrules.html<https://eur02.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.ieee-pses.org%2Flistrules.html=05%7C01%7Cdonald.gies%40se.com%7C91fb203f016b4a7b14d808dab2e41970%7C6e51e1adc54b4b39b5980ffe9ae68fef%7C0%7C0%7C638018989994406040%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000%7C%7C%7C=rwlwUMrfqCmun1L3fefsBkOLZFbdTFs9tG886n90fFE%3D=0>

For help, send mail to the list administrators:
Mike Cantwell mailto:mcantw...@ieee.org>>

For policy questions, send mail to:
Jim Bacher mailto:j.bac...@ieee.org>>
David Heald mailto:dhe...@gmail.com>>



To unsubscribe from the EMC-PSTC list, click the following link: 
https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC=1

-

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 


All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Mike Cantwell 

For policy questions, send mail to:
Jim Bacher:  
David Heald: 
_
To unsubscribe from the EMC-PSTC list, click the following link: 
https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC=1


[PSES] IEC 62368-1 ES3/PS3 cold impact test

2022-10-20 Thread Chris
Folks,
When do we need to do IEC 62368-1 ES3/PS3 cold impact test as per IEC 62368-1 
Third edition.
I was told if EUT is powered by ES3/PS3 then it is required.
any insight will be helpful
Thanks in advance
Christopher

-

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 


All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)