We did some EMC testing last week (radiated emission in a chamber) on a
ventilation system with two fans. It exceeded the limits on 145MHz.
Then outside the camber, we shut
We did some EMC testing last week (radiated emission in a chamber) on a
ventilation system with two fans. It exceeded the limits on 145MHz.
Then outside the camber, we shut down the fans, we found the 145MHz on a bus
line from a controller (3rd part product). Connecting the fans back again,
3 matches