Re: [PSES] Japanese manis leads

2018-12-31 Thread John Woodgate
Thank you very much. Best wishes John Woodgate OOO-Own Opinions Only J M Woodgate and Associates www.woodjohn.uk Rayleigh, Essex UK On 2019-01-01 02:17, T.Sato wrote: John, On Mon, 31 Dec 2018 17:42:39 +, John Woodgate wrote: Hello, Sato-san.  Since mains outlets rarely have PE

Re: [PSES] Japanese manis leads

2018-12-31 Thread T.Sato
John, On Mon, 31 Dec 2018 17:42:39 +, John Woodgate wrote: > Hello, Sato-san.  Since mains outlets rarely have PE terminals, is the > built-in wiring in homes also just 2-core (no PEC) for 100 V and > 3-core (no PEC) for 200 V? These days, o 200 V outlets (typically used for

Re: [PSES] Japanese manis leads

2018-12-31 Thread John Woodgate
Hello, Sato-san.  Since mains outlets rarely have PE terminals, is the built-in wiring in homes also just 2-core (no PEC) for 100 V and 3-core (no PEC) for 200 V? Best wishes for a happy and prosperous New Year. John Woodgate OOO-Own Opinions Only J M Woodgate and Associates www.woodjohn.uk

Re: [PSES] Japanese manis leads

2018-12-07 Thread John Woodgate
W's question. John E Allen West London, UK -Original Message- From: T.Sato [mailto:vef00...@nifty.com] Sent: 07 December 2018 22:35 To: john_e_al...@blueyonder.co.uk Cc: EMC-PSTC@LISTSERV.IEEE.ORG Subject: Re: [PSES] Japanese manis leads John, On Fri, 7 Dec 2018 14:40:26 -, "

Re: [PSES] Japanese manis leads

2018-12-07 Thread John Allen
: EMC-PSTC@LISTSERV.IEEE.ORG Subject: Re: [PSES] Japanese manis leads John, On Fri, 7 Dec 2018 14:40:26 -, "John Allen" wrote: > Ref those 200V products: are they single phase 2-wire (Neutral + Live) + > Ground, OR split-phase (100V on each of 2 Live legs) + Neutral

Re: [PSES] Japanese manis leads

2018-12-07 Thread T.Sato
s, Tom -- Tomonori Sato URL: http://t-sato.in.coocan.jp > -Original Message- > From: T.Sato [mailto:vef00...@nifty.com] > Sent: 07 December 2018 14:04 > To: EMC-PSTC@LISTSERV.IEEE.ORG > Subject: Re: [PSES] Japanese manis leads > > John, > > On Fri,

Re: [PSES] Japanese manis leads

2018-12-07 Thread Ted Eckert
Hello John, The vast majority of single-phase electrical outlets in Japanese residential and commercial installations have no protective earth. Most products sold in Japan are Class II. Outlets with protective earth are typically only found in industrial applications in Japan. Best regards,

Re: [PSES] Japanese manis leads

2018-12-07 Thread John Allen
appliances). John E Allen W. London, UK -Original Message- From: T.Sato [mailto:vef00...@nifty.com] Sent: 07 December 2018 14:04 To: EMC-PSTC@LISTSERV.IEEE.ORG Subject: Re: [PSES] Japanese manis leads John, On Fri, 7 Dec 2018 10:54:18 +, John Woodgate wrote: > In Japan, are 3-core

Re: [PSES] Japanese manis leads

2018-12-07 Thread John Woodgate
Thank you. Best wishes John Woodgate OOO-Own Opinions Only J M Woodgate and Associates www.woodjohn.uk Rayleigh, Essex UK On 2018-12-07 14:04, T.Sato wrote: John, On Fri, 7 Dec 2018 10:54:18 +, John Woodgate wrote: In Japan, are 3-core (L, N, PE) mains leads widely used for

Re: [PSES] Japanese manis leads

2018-12-07 Thread John Woodgate
Thank you. Best wishes John Woodgate OOO-Own Opinions Only J M Woodgate and Associates www.woodjohn.uk Rayleigh, Essex UK On 2018-12-07 14:04, T.Sato wrote: John, On Fri, 7 Dec 2018 10:54:18 +, John Woodgate wrote: In Japan, are 3-core (L, N, PE) mains leads widely used for

Re: [PSES] Japanese manis leads

2018-12-07 Thread T.Sato
John, On Fri, 7 Dec 2018 10:54:18 +, John Woodgate wrote: > In Japan, are 3-core (L, N, PE) mains leads widely used for > single-phase products or are the majority of products safety Class II, > with just L and N? At least for household products, majority of products are Class 0 and some