Re: [Emc-users] XSY inverters (VFD)

2022-09-23 Thread andy pugh
On Fri, 23 Sept 2022 at 20:10, Jon Elson wrote: > Does anybody know the XSY Inverters? > No, sorry, so anything I say will be rather generic. I have an XSY-AT1 Inverter (VFD) and I have it mostly > programmed just fine. To get good torque at lower speeds, I > turned up parameter P72 (Torque

[Emc-users] XSY inverters (VFD)

2022-09-23 Thread Jon Elson
Does anybody know the XSY Inverters? I have an XSY-AT1 Inverter (VFD) and I have it mostly programmed just fine.  To get good torque at lower speeds, I turned up parameter P72 (Torque compensation setting) and that worked great at the lowest speeds.  But, at higher speeds, the motor current

Re: [Emc-users] Emc-users Digest, Vol 197, Issue 50

2022-09-23 Thread Alan Condit
Thanks for any help, I found out that the power supply is OK. I was just not getting a good connection between my multimeter probes and the PSupply. I tested at the drives and the voltage was good. I put a new copy of my .ini and .hal file on pastebin. myPCBMill.ini