In the Integrators manual (2.2.6) look in 6.3.7 [Axis_num] Section. The
MAX_VELOCITY and MAX_ACCELERATION for the individual axis will not be
overridden no matter what the jog slider shows.
John
On 13 Aug 2008 at 17:05, Christopher Purcell wrote:
On a machine that has rather different axes,
On a machine that has rather different axes, with different maximum
velocities, I find it inconvenient that Axis
(as I know how to use it) seems to read only one value for
MAX_LINEAR_VELOCITY from the [TRAJ] section of the .ini file and uses
this to determine the Jog Speed range for all 3
HI,
What actually controls the jogging speed? - I'm sure I knew but my brain
is in Estop just now When I start up Axis, the jogging speed sliders
are at ridiculously high values and, if I forget to change them then the
axes give up half way through a move losing my position. G0 works fine
I think it's this:
your.ini
[TRAJ]
...
DEFAULT_VELOCITY = 0.xxx
...
For me it seems to set the initial jog slider setting. Although, you
should not be able to jog beyond operational limits if your other
settings are correct.
Such as:
your.ini
[TRAJ]
...
MAX_VELOCITY = x.xxx
...
and