On Wed, Apr 23, 2014 at 01:39:28PM +1200, Gavin Lambert wrote:
> On Tuesday, 22 April 2014 20:21, quoth Richard Hacker:
> > For the very simple reason, that the application can start without any
> > slaves being attached to the network!
>
> I thought it might be something like that. However this
On Tuesday, 22 April 2014 20:21, quoth Richard Hacker:
> For the very simple reason, that the application can start without any
> slaves being attached to the network!
I thought it might be something like that. However this seems of very
limited usefulness to me as there doesn't seem to be any wa
Am 04/22/2014 09:33 AM, schrieb Gavin Lambert:
Hi all,
TLDR: when reassigning PDOs, why doesn't the master read mappings from the
slave via CoE?
For the very simple reason, that the application can start without any
slaves being attached to the network!
In order to be able to do that, the ma
Hi all,
TLDR: when reassigning PDOs, why doesn't the master read mappings from the
slave via CoE?
I have a (custom) slave that provides a number of different PDOs. I have a
couple of different master applications which are interested in different
subsets of these PDOs. As an example, let's say