On Wed, 2007-12-05 at 08:18 -0800, Scott Weitzenkamp (sweitzen) wrote:
I'll open a bug.
All two port HCAs ? Are all of them the same 2 port PCIe model or are
there others ?
All type of 2 port PCIe HCAs (LionCub, LionMini, and Eagle).
Can you provide:
smpquery nodedesc
smpquery nodeinfo
and most importantly
perfquery -de
for a failed node/port ?
[EMAIL PROTECTED] ~]# perfquery -de
ibwarn: [18050] smp_query: attr 0x11 mod 0x0 route DR path 0
ibwarn: [18050] mad_rpc: data offs 64 sz 64
mad data
0101 0102 0005 ad00 0100 d050 0005 ad00
0020 0848 0005 ad00 0020 0849 0040 6282
00a0 0100 05ad
ibwarn: [18050] smp_query: attr 0x15 mod 0x0 route DR path 0
ibwarn: [18050] mad_rpc: data offs 64 sz 64
mad data
fe80
0005 0002 0251 0a68 000f 0103 0302
1452 0011 4040 0008 0804 f240
2008 10f0
ibwarn: [18050] pma_query: lid 5 port 1
ibwarn: [18050] mad_rpc: data offs 64 sz 192
mad data
0101 0014
ibwarn: [18050] main: PerfMgt ClassPortInfo 0x0 extended counters not
indicated
That's what I was afraid of and asked about on the list a while ago
(about whether there was such a use case and there is) :-(
Not sure exactly why this wasn't a problem prior to this change.
When was the last time you tried this on a subnet which included one or
more of these HCAs ?
So...
How important is fixing this (for OFED 1.3) ?
-- Hal
ibwarn: [18050] pma_query: lid 5 port 1
ibwarn: [18050] mad_rpc: MAD completed with error status 0xc
perfquery: iberror: [pid 18050] main: failed: perfextquery
___
ewg mailing list
ewg@lists.openfabrics.org
http://lists.openfabrics.org/cgi-bin/mailman/listinfo/ewg