On Tue, 26 Apr 2011 07:08:21 +0200, Denis Fortin wrote:
> Good morning,
>
> I have a small server with an SSD drive in it that is having some problems.
>
> Notably, dmesg has been repeatedly reporting the following error message:
>
> g_vfs_done():ad0s1a[READ(offset=-574217714356717568,
>
On Tue, 26 Apr 2011 07:08:21 +0200
Denis Fortin wrote:
> So, is there a way to "mark the inode bad" and then launch an fsck ?
> How can I turn "offset=-574217714356717568" into a usable piece of
> information?
It looks like something is causing geom to try and read way past the
end of the disk?
Good morning,
I have a small server with an SSD drive in it that is having some problems.
Notably, dmesg has been repeatedly reporting the following error message:
g_vfs_done():ad0s1a[READ(offset=-574217714356717568,
length=16384)]error = 5
I realize that the best course of action is t