FreeBSD 6.1 and RAID controller PERC 5/i in DELL PowerEdge 2950

2006-10-26 Thread Marthias, Santosso
Hello All, We have DELL PowerEdge 2950 with RAID controller PERC 5/i and 6 Fujitsu 73GB SAS disks. We created 3 RAID-1 virtual disks out of the 6 disks : VD0 = RAID-1 using disk0 and disk1 VD1 = RAID-1 using disk2 and disk3 VD2 = RAID-1 using disk4 and

Re: FreeBSD 6.1 and RAID controller PERC 5/i in DELL PowerEdge 2950

2006-10-26 Thread Erik Trulsson
On Thu, Oct 26, 2006 at 12:27:00PM -0600, Marthias, Santosso wrote: Hello All, We have DELL PowerEdge 2950 with RAID controller PERC 5/i and 6 Fujitsu 73GB SAS disks. We created 3 RAID-1 virtual disks out of the 6 disks : VD0 = RAID-1 using disk0 and disk1

Re: FreeBSD 6.1 and RAID controller PERC 5/i in DELL PowerEdge 2950

2006-10-26 Thread Paul Schmehl
--On Thursday, October 26, 2006 12:27:00 -0600 Marthias, Santosso [EMAIL PROTECTED] wrote: One thing is working, if we only use mfid0 for OS installation and leave (not use at all) mfid1 and mfid2, then the server rebooted fine after the OS installation (we get the login prompt). The problem