Hello Nandy,
thanks for your hint, but it's a bit more than that.
In our application which is handled via XML-Curl, the user can define
it's forwards on a web interface. He can enter mixed local or external
numbers which are called sequentially or in parallel.
Best regards
Peter
Nandy Dagondon
You definitely need to use the settings in combination for what you are trying
to do. Can you explain a bit more what you want to do in what conditions and
maybe we can suggest how to accomplish this. NORMAL_CLEARING is not a failure,
so it can continue on after the bridge unless you specify
set hangup_after_bridge=true
Mathieu Rene
Avant-Garde Solutions Inc
Office: + 1 (514) 664-1044 x100
Cell: +1 (514) 664-1044 x200
mr...@avgs.ca
On 7-Dec-09, at 1:31 PM, Peter P GMX wrote:
I have a Problem with continue_on_fail.
I have setup a hunt group
action application=set
I have a Problem with continue_on_fail.
I have setup a hunt group
action application=set data=continue_on_fail=NO_ANSWER,USER_BUSY/
action application=bridge
data=sofia/external/2...@10.11.12.243,sofia/external/2...@10.11.12.234,sofia/external/2...@10.11.12.188,sofia/external/1...@10.11.12.245/