Alexander Simbun [EMAIL PROTECTED] wrote:
I have not yet re-establish the SIC. To do so, I have to detach the
cluster member and re-initialize it again. Meanwhile, I'm also unable
to ping the physical IP of the cluster's member.
It is often the case that when you create a cluster, only the
Some time you may be unable to contact the cluster member if you
configure the external ip in the member object. Try using the internal
ip if the smartcenter server is inside your networkRamki
David DeSimone wrote:
Alexander Simbun [EMAIL PROTECTED] wrote:
I have not yet re-establish
If you can't ping the cluster member (assuming your rules allow it),
then you're not going to be able to re-establish SIC. You don't have
to detach the cluster member to do that. Just go onto the module, run
cpconfig and choose reset SIC from there. Then within SmartDashboard,
there is an
I have not yet re-establish the SIC. To do so, I have to detach the
cluster member and re-initialize it again. Meanwhile, I'm also unable to
ping the physical IP of the cluster's member. I will try to see whether
the re-establish the SIC do help to solve this problem. Thanks again.
Regards,