[FW-1] Unable to load R75.20 config in R75.40

2012-11-29 Thread Mohamed N. - T.I.
Hi, I am using the following and want to build a R75.40 Existing Firewall Details Stanby Firewall Details IP Appliance SmartCentre Server IP Appliance SmartCentre Server Model IP295 Hp Half Blade Model IP295 Hp Half Blade IPSO

Re: [FW-1] Unable to load R75.20 config in R75.40

2012-11-29 Thread pkc_mls
Le 29/11/2012 9:04, Mohamed N. - T.I. a écrit : Hi, I am using the following and want to build a R75.40 Hi Mohamed, Be sure to use r75.40 binaries to export the config from the r75.20. It means you have to copy $FWDIR/bin/upgrade_tools directory from r75.40 to r75.20. you can copy the

Re: [FW-1] gaia r75.45 - ftp with authentication poor performance

2012-11-29 Thread pkc_mls
Le 28/11/2012 7:20, Matthias Leu a écrit : Am 28.11.2012 15:19, schrieb pkc_mls: Hi, how do you authenticate? If you use e.g. UserAuth, the FTP Security Server is used. This might cost performance. Maybe you can try to use ClientAuth or define a rule using Access Roles with IA. Hope it helps,

Re: [FW-1] Unable to load R75.20 config in R75.40

2012-11-29 Thread Mohamed N. - T.I.
I will try and revert. -Mohd. 2380 moham...@fss.co.in +91 95001 29207 -Original Message- From: Mailing list for discussion

Re: [FW-1] Unable to load R75.20 config in R75.40

2012-11-29 Thread Simon Desmeules
Not exactly your problem but I did encounter this recently which the SK solution solved: Unable to restore backup file on fresh install of R75.40 Symptoms . Restore process fails with following error: The package selected for revert is version R75, which is incompatible with the current

[FW-1] R: Re: [FW-1] Unable to load R75.20 config in R75.40

2012-11-29 Thread Giacomo Fazio
I had similar problem. I solved upgrading to r75.45 an then restoring. Giacomo Le mail ti raggiungono ovunque con BlackBerry® from Vodafone! -Original Message- From: Simon Desmeules sdesmeu...@esitechnologies.com Sender: Mailing list for discussion of Firewall-1