Patch Set 2:
> Please also see http://osmocom.org/issues/1851 and
> http://osmocom.org/issues/1622 in this context
Thanks for pointing! I didn't realize we don't even follow the standard..
--
To view, visit https://gerrit.osmocom.org/3560
To unsubscribe, visit
Alexander Chemeris has submitted this change and it was merged.
Change subject: osmo-bts-trx: Fix MS power control loop.
..
osmo-bts-trx: Fix MS power control loop.
The following two commits from 2014-12-06 introduced a new
Patch Set 1:
Please also see http://osmocom.org/issues/1851 and
http://osmocom.org/issues/1622 in this context
--
To view, visit https://gerrit.osmocom.org/3560
To unsubscribe, visit https://gerrit.osmocom.org/settings
Gerrit-MessageType: comment
Gerrit-Change-Id:
Patch Set 1: Code-Review+2
--
To view, visit https://gerrit.osmocom.org/3560
To unsubscribe, visit https://gerrit.osmocom.org/settings
Gerrit-MessageType: comment
Gerrit-Change-Id: I713e39b882db32a0d17aa04790d16fa79afa1fb1
Gerrit-PatchSet: 1
Gerrit-Project: osmo-bts
Gerrit-Branch: master
Review at https://gerrit.osmocom.org/3560
osmo-bts-trx: Fix MS power control loop.
The following two commits from 2014-12-06 introduced a new variable to control
MS power - ms_power_ctrl, but kept the old ms_power variable in place. They
have also changed the meaning of the ms_power variable -