Dears Justin and Christopher
Thanks a lot,
I'll do the same.
Sincerely
--
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
* Please search the archive at
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
* Please don't post
Hi all,
I want to do Molecular dynamics simulation of a box of water (SPC
type). I get the spc216.pdb file from the gromacs/share/tutor.
Firstly, I did geometry optimization for nsteps= 5.
Now, can I continue with production run or do I need to do
equilibration runs to arrive correct
On 9/7/12 7:34 AM, Turgay Cakmak wrote:
Hi all,
I want to do Molecular dynamics simulation of a box of water (SPC
type). I get the spc216.pdb file from the gromacs/share/tutor.
Firstly, I did geometry optimization for nsteps= 5.
Now, can I continue with production run or do I need to do
Thanks a lot for your quick reply Justin. I got it.
Turgay
2012/9/7 Justin Lemkul jalem...@vt.edu:
On 9/7/12 7:34 AM, Turgay Cakmak wrote:
Hi all,
I want to do Molecular dynamics simulation of a box of water (SPC
type). I get the spc216.pdb file from the gromacs/share/tutor.
Firstly, I
Good day,
I was looking for the documentation for the .gro format but I couldn't find it
on the site or manual. I am missing something?I am trying to parametrize some
lipid ligands using ATB (http://compbio.biosci.uq.edu.au/atb) and I have been
creating the .gro files by trial and error. I
On 9/7/12 11:42 AM, Julio Dominguez wrote:
Good day,
I was looking for the documentation for the .gro format but I couldn't find it
on the site or manual. I am missing something?I am trying to parametrize some
lipid ligands using ATB (http://compbio.biosci.uq.edu.au/atb) and I have been
Dear All,
I want to use ACEMD software on GPUs which I have an access to. It
could take while before I would prepare system of interest in NAMD or
Amber Tool as I always used Gromacs.
Do you know whether there is an easy way to translate gro/pdb files
(equilibrated) and topology prepared in
Dear All,
I've been having some issues with energies with gromacs running on
various core counts for a 7469 polymer in solvent system, constraining
all bonds and running with a 2fs time step. I used PME-shift (1.05nm,
1.10nm), and a shift with the same parameters for the VdW, I am using
the
On 2012-09-06 02:46:21PM +0200, Bogdan Costescu wrote:
On Wed, Sep 5, 2012 at 8:37 PM, Peter C. Lai p...@uab.edu wrote:
Could be a result of not setting x/y compressibility = 0 as the manual
suggests you should do...
As one who has also tried to use walls recently, I've also found this
Thank you, Justin. I havenĀ“t thought of that.
Best regards. --
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
* Please search the archive at
http://www.gromacs.org/Support/Mailing_Lists/Search before posting!
10 matches
Mail list logo