On 25/11/2011 6:53 PM, James Starlight wrote:
This way I've already used but is this possible to extract Gro and trp
files from uncompleated runs and not stopping this simulation ?
Copy the trajectory file. Then use trjconv on the copy however suits
you. You don't need a new .tpr, you need
Hey,
You don't actually need to copy the trajectory. trjconv and other
tools are comfortable operating on an unfinished trajectory. They'll
just bail out at the end. As an alternative, here's a python one-liner
to extract the last frame (along with unfinished frames) from an XTC
trajectory:
Oh, I see I forgot to state that X should be set to the trajectory name:
X=/some/where/trajectory.xtc
python -c 'X=open('$X').read(); print X[X.rfind(X[:8]):]' last.xtc
or just
python -c 'X=open(/some/where/trajectory.xtc).read(); print
X[X.rfind(X[:8]):]' last.xtc
Cheers,
Tsjerk
On Fri,
Dear Gromacs Users!
At the present time I'm simulating small peptide (11 a.c in coiled
conformation) in water.
I've desided to use parameters from Lysozyme simmulation ( opls ff for
parametrisation and all mdp parameters from that simulation).
Because my peptide was smaller than typical
On 25/11/2011 5:22 PM, James Starlight wrote:
Dear Gromacs Users!
At the present time I'm simulating small peptide (11 a.c in coiled
conformation) in water.
I've desided to use parameters from Lysozyme simmulation ( opls ff for
parametrisation and all mdp parameters from that simulation).
Hi James,
There have been extensive discussions about this on the list. Check the
archives. In short, smaller systems give larger fluctuations, and shorter
simulations give larger deviations from the expected average.
Cheers,
Tsjerk
On Nov 25, 2011 7:23 AM, James Starlight
Mark, Tsjerk thanks!
I've check my uncompleated produced MD run by G_energy and find that
average pressure is 1.1 Bar that is most close to ref.
By the way could you tell me about extra possible ways of checking running
simmulation? ( E.g I'm calculating long produce trajectory and want to
On 25/11/2011 6:38 PM, James Starlight wrote:
Mark, Tsjerk thanks!
I've check my uncompleated produced MD run by G_energy and find that
average pressure is 1.1 Bar that is most close to ref.
By the way could you tell me about extra possible ways of checking
running simmulation? ( E.g I'm
This way I've already used but is this possible to extract Gro and trp
files from uncompleated runs and not stopping this simulation ?
James
2011/11/25 Mark Abraham mark.abra...@anu.edu.au
On 25/11/2011 6:38 PM, James Starlight wrote:
Mark, Tsjerk thanks!
I've check my uncompleated
9 matches