Hi Erast,
There is a new bug in the e1000g driver that does not allow flow
control to be advertised correctly. This means that link aggregates on
the x4100 don't work where there are two nge interfaces and two e1000g
interfaces. This seems to affect the latest Sol10U4 patches and the
Thanks for the information!
By any chance, do you have bug number for this? Could you look it up if
fix is already in?
On Wed, 2008-04-09 at 13:52 -0700, Tim Spriggs wrote:
Hi Erast,
There is a new bug in the e1000g driver that does not allow flow
control to be advertised correctly.
Hi Erast,
My boss has a an open request with Sun for Solaris 10 support but
haven't heard back in the past week/two I'll ask him if there is a
related bug id. The root of the problem is:
#ndd -get /dev/nge0 adv_asym_pause_cap
1
#ndd -get /dev/e1000g0 adv_asym_pause_cap
0
(I'm told both