On 4/28/15 1:29 AM, Biplab Ghosh wrote:
Dear All,
I am a beginner in MD and started with Gromacs. I would like to simulate
the dynamics of a homo-dimeric
protein containing 2 Mn atoms at the active site. I would appreciate any
sorts of help in this regards, e.g.,
please share your experience
Hi,
Typically that means you're reading a trajectory of size 2GB on a
filesystem that can't do that (e.g. a 32-bit one).
Mark
On Tue, Apr 28, 2015 at 4:20 PM Jennifer Vo quyvio...@gmail.com wrote:
Dear All,
I have got the error in the end of trajectory converting: Magic Number
Error in XTC
Dear Mark,
Many thanks for your answer. Is there anyway to overcome this?
Regards,
Jennifer
On Tue, Apr 28, 2015 at 4:26 PM, Mark Abraham mark.j.abra...@gmail.com
wrote:
Hi,
Typically that means you're reading a trajectory of size 2GB on a
filesystem that can't do that (e.g. a 32-bit one).
Hi,
we use half-harmonic distance restraints between COM of a solute and a
number of waters around it.
Does Gromacs (gromacs-4.6.3) account for the contribution of these
inter-molecular distance restraints to the virial?
Where can it be found/included in the code? In disre.c ?
We found the
If that's the problem, use a machine with a real file system ;-)
Mark
On Tue, Apr 28, 2015 at 4:34 PM Jennifer Vo quyvio...@gmail.com wrote:
Dear Mark,
Many thanks for your answer. Is there anyway to overcome this?
Regards,
Jennifer
On Tue, Apr 28, 2015 at 4:26 PM, Mark Abraham
Dear All,
I have got the error in the end of trajectory converting: Magic Number
Error in XTC file (read -335790888, should be 1995)
trjconv -s md-1.tpr -f md-300ns-wat.xtc -o md_CA.pdb -n index_8pro.ndx -pbc
mol -ur compact -center -skip 1000
Is there anybody know what`s the error about?
Many
On 4/27/15 10:06 PM, Brett wrote:
Dear All,
In the MD mdp file for the old version of on-line tutorials for lysozyme, in the neighbor search,
there is an item rlist, but in the MD mdp file for the new version of on-line tutorials
for lysozyme, in the neighbor search, there is no item rlist.
Hi,
we have determined the Mn2+ OPLSA sigma and epsilon parameters in
http://onlinelibrary.wiley.com/doi/10.1002/anie.201202032/suppinfo
following the procedure reported here
http://pubs.acs.org/doi/abs/10.1021/jp064835t
hope it helps
and
On 28/04/2015 14:12, Justin Lemkul wrote:
On
Hi all,
I am a beginner to GROMACS and MD simulations in general. I’m trying to
model electroporation in a DPPC membrane but I am having issues with the
energy minimization step. I am basing my approach on the one followed in
Dr. Justin Lemkul’s KALP-15 in DPPC Tutorial (
Dear allI am using gromacsto simulate ligand bonding to an enzyme. I have two
problems withcharge of system: 1) after making topology file for ligand using
prodrug, I saw itsnet charge was -0.4. how can I neutralize it?2) I used this
topology parameters of ligand to continuesimulation steps.
Hi Rajan,
NMA/GNM is performed on a single structure, not on a trajectory. NMA can be
performed with Gromacs, but GNM/ENM is not possible, AFAIK.
Cheers,
Tsjerk
On Apr 28, 2015 5:07 PM, rajan kumar choudhary rajugunju...@gmail.com
wrote:
Dear all,
Is it possible to perform Normal mode
Dear all,
Is it possible to perform Normal mode analysis and GNM analysis with
gromacs trajectory file in GROMACS or somewhere else. any help in this
regard will be very appreciated.
thank you all
--
*Rajan kumar choudhary*
*Senior Research Fellow*
*Department of Atomic Energy(Govt.Of
Hi Tsjerk,
Thank your for your help. I could get over the issue. :)
Regards,
Sapna.
On Tue, Apr 28, 2015 at 11:44 AM, Tsjerk Wassenaar tsje...@gmail.com
wrote:
Hi Sapna,
Check
http://www.gromacs.org/Documentation/Terminology/Periodic_Boundary_Conditions
Cheers,
Tsjerk
On Apr 28, 2015
On 4/28/15 11:14 AM, Emran Heshmati wrote:
Dear allI am using gromacsto simulate ligand bonding to an enzyme. I have two
problems withcharge of system: 1) after making topology file for ligand using
prodrug, I saw itsnet charge was -0.4. how can I neutralize it?2) I used this
If the net
On 4/28/15 8:14 AM, Abhijit Jassem wrote:
Hi all,
I am a beginner to GROMACS and MD simulations in general. I’m trying to
model electroporation in a DPPC membrane but I am having issues with the
energy minimization step. I am basing my approach on the one followed in
Dr. Justin Lemkul’s
If I use PME there's no need to find epsilon-rf, but I have to change some
other parameters. I will try it.
Thank you very much Alex!
On Tue, Apr 28, 2015 at 11:31 AM, Alex nedoma...@gmail.com wrote:
With reaction-field-zero, the only option is epsilon-rf=0. That aside,
if the nanotube is
Good Afternoon,
Recently i saw in a paper that SAXS guided MD was implemented in Gromacs.
Here is the paper - http://pubs.acs.org/doi/full/10.1021/ct5009735
I could not find any info on this. Does anyone have any information about
this subject?
Thank you,
Tiago
--
Gromacs Users mailing list
*
Hi Mark,
Thanks for the reply. In my previous message, one molecular component of my
liquid solution greatly-deforms (explodes) on energy minimization. I
have examined the topology and everything seems in order. No warnings were
generated by grompp or mdrun. Here are my minimization settings:
That's a pretty poorly formed question, including the part where you
actually calculate the epsilon-rf value. Can you please try again with
a description of your system?
Alex
MK Dear all,
MK I use reaction-field-zero as the coulombtype for my system. I wonder how I
MK should choose the right
With reaction-field-zero, the only option is epsilon-rf=0. That aside, if the nanotube is small, i would use cut-off electrostatics with coulomb-cutoff comparable to the length of the tube.
If the tube is long, I would use standard pme. I would be extremely careful about using truncated
Dear all,
I use reaction-field-zero as the coulombtype for my system. I wonder how I
should choose the right epsilon-rf. How can I calculate the dielectric
constant in the system?
Thank you.
--
Gromacs Users mailing list
* Please search the archive at
Hi,
What happens when you use this topology on a single molecule? Other
standard techniques for diagnosing at
http://www.gromacs.org/Documentation/Terminology/Blowing_Up
Mark
On Tue, Apr 28, 2015 at 8:09 AM, Eric Smoll ericsm...@gmail.com wrote:
Hi Mark,
Thanks for the reply. In my previous
Also, reaction-field-zero, as described here
http://manual.gromacs.org/online/mdp_opt.html
which _only_ works with epsilon-rf=0. Any particular reason for doing
this to your electrostatics?
Alex
MK Dear all,
MK I use reaction-field-zero as the coulombtype for my system. I wonder how I
MK
23 matches