Look for any "MISSING ATOMS" in the pdb file (in the REMARKS).
Look at the coordinates given for the LYS in question and check if there are
coordinates for the CG.
Experimental data isn't "perfect." PDB entries have missing residues and
missing atoms all the time because they couldn't be
Hi,
On Thu, Jan 7, 2016 at 11:30 AM Hubert Santuz
wrote:
> Hi Mark,
>
> You were right, MPT defines a constant UNDEFINED in their mpi++.h Why it
> should not do?
>
Because if everybody wrote libraries like that, then nobody could use any
generic-sounding name for a
Hii Justin..
Since I am using PME option in my both simulation (Bound as well as alone),
I think that it is necessary to use rerun option brfore parsing the values
to g_lie. When I am running mdrun with new .mdp settings without PME option
I am getting series of warnings and therefore program
Hi,
No, I don't have access to the MPT documentation, so you should start
there. I would be pretty sure it wouldn't be faster, either ;-)
Mark
On Thu, 7 Jan 2016 13:25 Hubert Santuz wrote:
> Hi,
>
> 2016-01-07 11:48 GMT+01:00 Mark Abraham :
>
On 1/7/16 5:54 AM, shagun krishna wrote:
Hii Justin..
Since I am using PME option in my both simulation (Bound as well as alone),
I think that it is necessary to use rerun option brfore parsing the values
to g_lie. When I am running mdrun with new .mdp settings without PME option
I am getting
Hi,
2016-01-07 11:48 GMT+01:00 Mark Abraham :
> Hi,
>
> On Thu, Jan 7, 2016 at 11:30 AM Hubert Santuz
> wrote:
>
> > Hi Mark,
> >
> > You were right, MPT defines a constant UNDEFINED in their mpi++.h Why it
> > should not do?
> >
>
> Because if
Finally, I found a solution by digging on MPT C++ bindings.
In fact, at the end of the MPT mpi.h file, we have:
if !defined(MPI_NO_CPPBIND)
#include "mpi++.h"
#endif
So MPT expose the C++ bindings by default.
To prevent that, I add the macro to src/gromacs/utility/gmxmpi.h :
/* MPI C++ binding
Dear Users,
I use GROMACS to do SMD simulation. I have the pullf.xvg file , but it is
very large. I also have the smd.xtc file. I have used it to calculate the
COM separation distance between the two pulled groups.
I want to plot force vs COM separation.
Can I calculate the pull force from the
Hiii Justin,
Thank you very much for your help. After changing my settings according to
your suggestions I am not getting the previous errors. :) The grompp
command ran successfully, but when I am evoking the mdrun using rerun
option I am getting a fatal error. Please have a look at my terminal
Dear Gromacs Users,
I'd like to prepare my system for MD simulations. I have non-standard
residue. I prepared a topology and coordinates by antechamber. I know, I
should add it to itp file. But what exactly I should do?
Thank you in advance,
Marta
--
Gromacs Users mailing list
* Please search
Dear Gromacs Users,
I did NPT simulations with a system containing 15000 atoms of polymers.
Initially, conf.gro was visualized in VMD and showed all connections are
OK. However, the confout.gro (final output configuration) seems to look
bad. Some of bonds are disconnected at the outer surface
Good evening everyone,
I was trying to generate the topology of the ligand binding domain of the
human androgen receptor (3B68) with pdb2gmx using
pdb2gmx -f 3b68.ent -o ar.gro -p ar.top -ignh
using the AMBER-ILDN ff and implict solvent (therefore typing 6 and 6 again
on gromacs v. 4.6.5) and it
Great. Thanks.
Hubert
2016-01-07 18:33 GMT+01:00 Mark Abraham :
> Hi,
>
> Thanks, I have now proposed that fix at https://gerrit.gromacs.org/5535.
> If
> accepted, it'll be in GROMACS 5.1.2
>
> Mark
>
> On Thu, Jan 7, 2016 at 6:05 PM Hubert Santuz
Hi,
It could just be missing from the experimental data. You'll need to do some
detective work about that pdb entry.
Mark
On Thu, 7 Jan 2016 19:05 Simone Bolognini wrote:
> Good evening everyone,
> I was trying to generate the topology of the ligand binding domain of
Hi All,
I am trying to reproduce the Cartesian PCA results for ALA3 in water by
Altis et al. (Fig.2 of Dihedral angle principal component analysis of
molecular dynamics simulations. http://dx.doi.org/10.1063/1.2746330 )
It is probably the most well-known PCA analysis results. I created a system
Hi Bin,
The procedure is correct, provided you ensured that the input trajectory
did not have PBC jumps. But the paper you refer to is on dihedral angle
PCA...
Cheers,
Tsjerk
On Jan 7, 2016 23:06, "Bin Liu" wrote:
> Hi All,
>
> I am trying to reproduce the Cartesian
16 matches
Mail list logo