Greetings
I have just recently started to work on this workstation (details as shown
below) and have employed all-atom simulation of 30,000 atoms with this
command (just for 1 micro-sec),
gmx mdrun -deffnm md -v -ntmpi 2 -ntomp 6 -gpu_id 01 -pin on
Running on 1 node with total 8 cores, 16
Hi Thanh,
Maybe try to check if the numbering of your atoms in the topology files is
consistent with the .pdb or .gro files they describe.
Billy
On 1 July 2016 at 09:20, Thanh Le wrote:
>
> > On Jun 30, 2016, at 3:48 PM, Thanh Le wrote:
> >
> >
Hi,
I am running a 100ns-REMD with 50 replicas. when continuing the REMD by
appending to the old output files, such error happened: "Fatal error:Failed to
lock: md1.log. Already running simulation?”
Then I had a test of 5 replicas. I limit the run time for 10 minutes
for every
> On Jun 30, 2016, at 3:48 PM, Thanh Le wrote:
>
> My name is Thanh Le, a graduate student in chemistry. Currently, I am using
> gromacs to do a dynamics simulation for my RNA-protein complex. I saw you
> posted a question titled “Atoms in the .top are not numbered
On 6/30/16 6:47 PM, Thanh Le wrote:
Hi Gandhi,
My name is Thanh Le, a graduate student in chemistry. Currently, I am using
gromacs to do a dynamics simulation for my RNA-protein complex. I saw you
posted a question titled “Atoms in the .top are not numbered consecutively from
1” on gromacs
Hi,
Run with one rank, e.g. gmx mdrun -ntmpi 1
Mark
On Thu, Jun 30, 2016 at 6:11 PM zeineb SI CHAIB
wrote:
> Dear Mark,
>
> Thank you for your orientation. I looked in Google and based on what you
> advised me, I prepared the following mdp file
>
> integrator = steep
>
Dear Mark,
Thank you for your orientation. I looked in Google and based on what you
advised me, I prepared the following mdp file
integrator = steep
nsteps = 1000
emtol = 1000.0
emstep = 0.01
energygrps= system
pbc = no
nstlist = 0
ns-type = simple
rlist = 0
Hi,
Best practice is to read and learn others practice from publications that
are similar to what you want to do, rather than making ad-hoc changes. In
this case, the GROMACS defaults are pretty close to the de facto standard,
and supported by analysis work done by other members of the community.
Dear Justin,
Thanks a lot for pointing out the issues. I now understand why there were
such high oscillations.
Could you please also tell me if there are any ideal values for pme_order
and fourier spacing with respect to the cut offs' value of 1.4.
Does the following Note imply I can raise the
On 6/30/16 9:16 AM, NISHA Prakash wrote:
Dear Justin,
Thank you for your reply.
It is a protein carbohydrate system. Including the solvent, the number of
atoms is 43499.
I have minimized the system for 200 ps followed by NPT and NVT simulations
for 200 ps respectively
Given that your
Dear Justin,
Thank you for your reply.
It is a protein carbohydrate system. Including the solvent, the number of
atoms is 43499.
I have minimized the system for 200 ps followed by NPT and NVT simulations
for 200 ps respectively
Below is the .mdp file.
; VARIOUS PREPROCESSING OPTIONS
title
On 6/30/16 8:58 AM, Sanja Zivanovic wrote:
Dear users,Could you please tell me if it is possible to make gmx rmsdist
without hydrogens, comparing just heavy atoms?
Supply an index file with a group that contains the atoms you want to use.
-Justin
--
Dear users,Could you please tell me if it is possible to make gmx rmsdist
without hydrogens, comparing just heavy atoms?
Thanks in advance a lot
Best Regards, Sanja
--
Gromacs Users mailing list
* Please search the archive at
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before
On 6/30/16 8:46 AM, NISHA Prakash wrote:
Dear all,
I have conducted a 10ns REMD simulation for a protein ligand complex with
the temperature range - 270 to 350 K, however the temperature distribution
plot of the replicas show that the sampling has occurred at higher
temperatures as well that
Dear all,
I have conducted a 10ns REMD simulation for a protein ligand complex with
the temperature range - 270 to 350 K, however the temperature distribution
plot of the replicas show that the sampling has occurred at higher
temperatures as well that is beyond 350K -
Below is an excerpt from the
Hi,
Yes, but it runs the same code.
Mark
On Thu, Jun 30, 2016 at 2:01 PM Nikhil Maroli wrote:
> Thanks, MARK,
>
> but I saw it is "Pascal." is that new Archi. ?
>
>
>
> --
> Gromacs Users mailing list
>
> * Please search the archive at
>
Thanks, MARK,
but I saw it is "Pascal." is that new Archi. ?
--
Gromacs Users mailing list
* Please search the archive at
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!
* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists
* For (un)subscribe
Hi,
Only if that makes a sensible model physics... But probably this is a
problem in the (user-contributed) port of amber14sb (and there are others,
including that they haven't updated the documentation files in it, so it
claims to be something else). The alpha carbon has a new type, so probably
Dear Gromacs users,
I am running Gromacs using the amber14sb force field. Amber distinguishes
histamine residues according to their protonation state into HIE, HID, and
HIP.
But then Gromacs complains for HID residues: No default Improper Dih. types
Do I have to do something additional or should
Hi,
Google has some good suggestions for examples for GROMACS mimization in
vacuo. You want no PBC, simple grid and maybe no cutoffs.
EM has no time, so time step is not a relevant concept. The .mdp option
documentation is quite useful...
Mark
On Thu, Jun 30, 2016 at 12:15 PM zeineb SI CHAIB
Hi,
Yes, it works already. There's no architectural change that would break
things.
Mark
On Thu, Jun 30, 2016 at 12:01 PM Nikhil Maroli wrote:
> HI,
> Thanks
>
> I have seen 1070 is much better than gtx 980ti and cheap also, released ?
> but it will support GROMACS or MD?
Dear Mark,
Thank you very much for your answer.
I'm trying to minimize my protein in vacuo but I'm havig problem to undrstand
the concept of "in vacuo" so I'm enable to construct an mdp file and I can't
found valid examples in forums and internet. Could you help me with that please?
Also,
HI,
Thanks
I have seen 1070 is much better than gtx 980ti and cheap also, released ?
but it will support GROMACS or MD? Since it released a few months ago?
Thanks
--
Gromacs Users mailing list
* Please search the archive at
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before
23 matches
Mail list logo