Thank You
On Fri, Sep 22, 2017 at 1:35 PM, Erik Marklund
wrote:
> Dear Tsaneem,
>
> Negative values don’t signify lack of correlation, but anticorrelation.
> Also, by omitting negative values you introduce a slight bias in your fit
> towards longer half-life.
>
> Kind regards,
> Erik
> _
Hi Gromacs Users,
I'm learning how to run a simple replica exchange MD simulation on my own
computer. My computer has 12 Xeon E5-2630 CPUs and 1 GeForce GTX 770 GPU.
I used to compile gromacs without the -DGMX_MPI option and it runs fine for
normal MD. I can control the number of CPUs to use by s
On 22/09/17 16:59, Sim gmx wrote:
First of all, thanks for your replies!
1) Indeed, both epsilon-r and epsilon-rf are such constants. However, in
the paper I guess that they refer to the relative dielectric constant of
the reaction field, i.e. epsilon-rf. Or do I miss something ?
Yes, they ar
Dear Gromacs users,
I am doing a simulation on inverted hexagonal (HII) phase composed of just
lipids and water.
(please have a look at HII phase here:
https://openi.nlm.nih.gov/detailedresult.php?img=PMC2695813_1757-5036-2-3-3&req=4
)
My question is regarding the pressure coupling for such syst
First of all, thanks for your replies!
1) Indeed, both epsilon-r and epsilon-rf are such constants. However, in
the paper I guess that they refer to the relative dielectric constant of
the reaction field, i.e. epsilon-rf. Or do I miss something ?
2) I will for sure contact them to collect all the
Hi,
In addition to Mark's comments, there are a few other points to be aware of:
1. If you use the twin-range scheme (i.e. 0.8/1.4) with nstlist 5, you need to
set nstcalclr to 1 to get results matching those as reported by Poger and
co-workers (see
http://pubs.acs.org/doi/abs/10.1021/acs.jctc
Hello Everyone
I have simulated a protein - ligand complex with gromacs 5.1.4 for 100ns.
I have restrained the position of the ligand ( which in my case is
hydrogen peroxide).
Applied following commands for correcting pbc:
gmx_mpi trjconv -f md.xtc -s md.tpr -pbc -nojump -o file1.xtc
gmx_mpi t
Hi,
On Fri, Sep 22, 2017 at 10:21 AM Sim gmx wrote:
> Hi!
>
> I would like to do simulations of lipids bilayers with gromos54a7
> parameters. To do so, I want to use the same mdp parameters as Poger et al.
> (the authors).
>
> In their papers, they write : "Nonbonded interactions were evaluated
Hi all,Where can I get gromos87 parameter file, with all atom types
and atom definitions (.atp) file, similar to the one gromacs provides in
gromacs/share/top/forcefiled.ffI understand the advantages and disadvantages of
using gromos87, still I want to use the for
Hi!
I would like to do simulations of lipids bilayers with gromos54a7
parameters. To do so, I want to use the same mdp parameters as Poger et al.
(the authors).
In their papers, they write : "Nonbonded interactions were evaluated using
a twin-range cutoff scheme: interactions falling within the 0
Dear Tsaneem,
Negative values don’t signify lack of correlation, but anticorrelation. Also,
by omitting negative values you introduce a slight bias in your fit towards
longer half-life.
Kind regards,
Erik
__
Erik Marklund, PhD, Marie Skłodowska Curie
11 matches
Mail list logo