An otherwise perfectly well-behaved setup is doing something catastrophic.
The pull code is:
; Pull code
pull = yes
pull-coord1-type = umbrella
pull_ngroups= 2
pull_ncoords= 1
pull_group1_name= K
pull_group2_name= CNT
... and everything is segfaulting, though worked perfectly fine until the
'cylinder' thing.
On Wed, Apr 18, 2018 at 3:45 PM, Alex wrote:
> Which then would be = 0 0 1, correct? This though will have to coexist
> with pull_coord1_rate= 0.0
>
> Is that reasonable?
>
>
Which then would be = 0 0 1, correct? This though will have to coexist with
pull_coord1_rate= 0.0
Is that reasonable?
Thanks,
Alex
On Wed, Apr 18, 2018 at 2:11 PM, Justin Lemkul wrote:
>
>
> On 4/18/18 4:08 PM, Alex wrote:
>
>> In addition, we seem to have a
I would try to tune your launch with a ~100 ps run, testing several
different options for optimal performance (it can really save some time).
Performance will be very dependent on your CPUs in the setup that you
mentioned, so I would recommend installing GROMACS 2018 to offload PME to
the GPU,
On 4/18/18 4:08 PM, Alex wrote:
In addition, we seem to have a different problem:
Cylinder geometry requires the use of pull-coord1-vec, not pull-coord1-dim.
-Justin
---
Program: gmx grompp, version 2018
Source file:
In addition, we seem to have a different problem:
---
Program: gmx grompp, version 2018
Source file: src/gromacs/gmxpreprocess/readpull.cpp (line 234)
Fatal error:
With pull geometry cylinder the pull vector can not be 0,0,0
On Wed, Apr
This is the exact situation that the "cylinder" pull geometry is
designed to model. I suggest going that route rather than ad hoc
restraints, which will influence the PMF and should be otherwise
accounted for.
-Justin
Hi Justin,
Thanks. To make sure things are more or less reasonable, I'd
Hi Mark,
Thanks for responding. I have filed an issue on redmine.gromacs.org
Best regards,
Tai
-Original Message-
From: gromacs.org_gmx-users-boun...@maillist.sys.kth.se
[mailto:gromacs.org_gmx-users-boun...@maillist.sys.kth.se] On Behalf Of Mark
Abraham
Sent: 18 April 2018 15:28
To:
Hi,
As far as I know nothing relevant should have changed, but if you would
like us to investigate further, please open an issue at
https://redmine.gromacs.org/ and attach the .tpr files that used to work
and now do not. Your 2018.x .log files might also be helpful.
Thanks!
Mark
On Wed, Apr
Dear all,
I am using gromacs version 2018 and 2018.1. However I figured that when I
freeze a group of atoms/molecules (water) using freezegrps (NVT ensemble), the
frozen atoms kept moving and the simulation terminated due to too many LINCS
warnings. This problem never happened before for
On 4/18/18 8:57 AM, Dawid das wrote:
The quick and dirty solution is that I write gro and g96 and copy
coordinates from the latter to the former, but I'd rather
have more elaborate solution.
.gro files are fixed-format, and in current GROMACS versions it is not
possible to write more
On 4/18/18 5:49 AM, za...@tezu.ernet.in wrote:
Dear Mark
Thank you for the kind response.
H with +0.418 charge and N with -0.845 charge is contributing towards
coulomb 14 interaction. So what is the amount of interaction between
one
single H and N (3 bonds apart)? Kindly correct me if I am
On 4/18/18 3:17 AM, Alex wrote:
I suppose this question is mostly for Justin...
Let me remind what I am dealing with and ask if my idea is correct.
I have a rectangular membrane in XY with a pore at (X/2, Y/2) in water
and want to get the Gibbs free energy curve for an ion. For this, I
The quick and dirty solution is that I write gro and g96 and copy
coordinates from the latter to the former, but I'd rather
have more elaborate solution.
2018-04-18 14:53 GMT+02:00 Dawid das :
> Dear All,
>
> I have similar issue. I have created xtc file with precision of
Dear All,
I have similar issue. I have created xtc file with precision of 1.0e-6 nm
and I want my gro file to have the same precision,
and I get this at the end of trjconv
Reading frame 0 time3.000
Precision of npt-md-prod.xtc is 1e-06 (nm)
Setting output precision to 1e-06 (nm)
Last
Hi,
On Wed, Apr 18, 2018 at 10:50 AM wrote:
> >> Dear Mark
> >> Thank you for the kind response.
> >> H with +0.418 charge and N with -0.845 charge is contributing towards
> coulomb 14 interaction. So what is the amount of interaction between
> one
> >> single H and N (3
> Hi,
>
> Probably something like an upgrade of the OS or compiler version changed
> the libraries that it linked to at run time and somehow the checks to
> prevent such problems didn't work. If you would recompile GROMACS on that
> machine, it would likely be fine.
Hey Mark,
Thanks for the
>> Dear Mark
>> Thank you for the kind response.
>> H with +0.418 charge and N with -0.845 charge is contributing towards
coulomb 14 interaction. So what is the amount of interaction between
one
>> single H and N (3 bonds apart)? Kindly correct me if I am wrong.
Thank you Justin for your kind
Hi,
>From the topology
Mark
On Tue, Apr 17, 2018, 22:05 Eric Smoll wrote:
> Hello Gromacs Users,
>
> When setting "constraints=h-bonds" in an mdp file, what sets the
> constrained bond length? Is it the equilibrium bond length in the topology,
> the bond length deduced
Hi,
Probably something like an upgrade of the OS or compiler version changed
the libraries that it linked to at run time and somehow the checks to
prevent such problems didn't work. If you would recompile GROMACS on that
machine, it would likely be fine.
Mark
On Wed, Apr 18, 2018, 05:37 Syed
On Thu, Apr 12, 2018 at 4:47 PM wrote:
>
>> Dear Gromacs Users
>>
>> We have a GPU Server (Intel(R) Xeon(R) CPU E5-2609 v4 @ 1.70GHz, 16
>> cores)
>> with 2 NVIDIA Tesla P100 (12GB) cards.
>>
>> What should be my final mdrun command so that it should utilize both the
>>
I suppose this question is mostly for Justin...
Let me remind what I am dealing with and ask if my idea is correct.
I have a rectangular membrane in XY with a pore at (X/2, Y/2) in water
and want to get the Gibbs free energy curve for an ion. For this, I have
a bunch of starting
22 matches