Dear Gromacs experts,
Does anyone know if there is a way to remove center of mass motion in
particular direction(s) only? Actually, I would like to remove system COM
movements in X and Y directions only, while letting the system move as it
likes in Z direction. As far as I can understand
Dear Users,
I want to simulate POPC membrane with CHARMM ff using GROMACS 4.6.5.
but in CHARMM ff directory, there is no popc itp file. How can I proceed?
Best,
H.A
--
Gromacs Users mailing list
* Please search the archive at
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before
On 11/24/14 3:00 AM, Mikhail Stukan wrote:
Dear Gromacs experts,
Does anyone know if there is a way to remove center of mass motion in
particular direction(s) only? Actually, I would like to remove system COM
movements in X and Y directions only, while letting the system move as it
likes
On 11/24/14 3:13 AM, h.aliza...@znu.ac.ir wrote:
Dear Users,
I want to simulate POPC membrane with CHARMM ff using GROMACS 4.6.5.
but in CHARMM ff directory, there is no popc itp file. How can I proceed?
Download the CHARMM36 files from our site:
Hi Wahab
I do have Gromacs-4.6.3 installed on my cygwin but there also I am able to
run all commands of gromacs except mdrun. sending the out put and mdlog of
mdrun for 4.6.3.
I do need Gromacs 4.5.4 as I have some comments in my paper where all work
is done on this version. Please help.
Hi guys!
Consider the atoms 1, 2 and 3 forming a triangle: I was wondering how can I
calculate the barycenter of this triangle using the atoms coordinates?
I want to measure the distance through time but I am not sure if there is a
simple way to do it.
Cheers!
--
Marcelo
Biochemicist
Dear Users,
I am just resending the email.
Constraining the CM of a molecules is a basic need of MD. Is that feature
not available in Gromacs ?
Thank you.
On Wed, Nov 19, 2014 at 11:20 AM, Sridhar Kumar Kannam srisri...@gmail.com
wrote:
Hi All,
Is there a way to restraint the CM of a
On 11/24/14 7:13 PM, Sridhar Kumar Kannam wrote:
Dear Users,
I am just resending the email.
Constraining the CM of a molecules is a basic need of MD. Is that feature
not available in Gromacs ?
You can accomplish something like this with the pull code, using no reference
group, so each
Hai gromacs users,
Can we use the direction-periodic mdp option
while running the samplling of windows instead of distance. The distance
option was giving error that
Distance of pull group 1 (15.017257 nm) is larger than 0.49 times the box
size (15.033495) .
So, for