On 8/2/18 7:36 PM, paul buscemi wrote:
Dear Users,
Although topogen is a bit dated it seems to work well for ‘smaller’ polymers
-500 atoms- and builds a single file itp. However in making a file for nylon 12
1000 atoms , a ‘central’ itp was create and separate files were made for
On 8/3/18 3:57 AM, Quyen V. Vu wrote:
Hi,
please check this:
http://www.gromacs.org/Documentation/Terminology/Pressure
Usually, if your system contains more than one element, use one thermostat
and barostat for solvent, one for the solution will give you more precise
instead of group system
Hi,
You can play around with the -radius and -scale parameters if you're
getting clashes you don't like.
However, it seems like you really should be using gmx solvate. You could
accomplish your goal with
"gmx solvate -cs tip4p.gro -box 10.1103 10.34753 3.958 -maxsol 13853"
Kevin
On Fri,
What version of MPI do you have? It may be helpful to indicate exact
location of MPI if the paths are not automatically found.
On 08/03/2018 02:43 PM, 郭聪 wrote:
Hi All,
I wanted to build GROMACS-2016.4 on hpc clusters but I got error with
domdec.cpp. Could anyone helps me with that?
Hi All,
I wanted to build GROMACS-2016.4 on hpc clusters but I got error with
domdec.cpp. Could anyone helps me with that? Thanks!
ps: I succeeded to build it on my lab pc. I am wondering if something is wrong
with GROMACS code or the compiler. I used gnu and openmpi.
tar -zxvf
I have one water molecule in my gro file as below:
TIP4P
4
1SOL OW1 0.054 0.005 0.022
1SOLHW12 0.009 0.072 0.073
1SOLHW23 0.142 0.041 0.008
1SOL MW4 0.060 0.018 0.026
0.00 0.000 0.000
Hi,
please check this:
http://www.gromacs.org/Documentation/Terminology/Pressure
Usually, if your system contains more than one element, use one thermostat
and barostat for solvent, one for the solution will give you more precise
instead of group system for all
On Fri, Aug 3, 2018 at 2:14 PM
I think calling this community "customers" is very funny. ;)
Pressure fluctuations depend on the system composition, size its
starting state (how well and for how long it was equilibrated), and many
other things. Further, pressure is not supposed to be dead-on constant
and some degree of
Hello,
what do you mean with the pressure not being constant? If you mean the
fluctuations in the instantaneous pressure, this is normal. What should
be constant is the time average of the pressure over the time of the
simulation.
I don't see anything particular in your mdp file that could
Dear all customers.
I have a problem, in my NPT simulations the pressure is not constant and
the temperature is. Earlier simulation in NVT conditions was ok. I use
these parameters:
tcoupl = nose-hoover
tc_grps = system
tau_t = 0.002
ref_t
Dear Gromacs Users,
My system contains two micelles. In order to calculate the radius of gyration
for two micelles, I need to select molecules in each micelle. Is there any tool
available in Gromacs to do that? If available, what options in the -h should I
use to get the information I want.
11 matches
Mail list logo