Hello,
please upload the log file from the run, as well as the command you used to
run the simulation and your system specs (processor, whether you are using
GPUs).
Then we can see what is wrong here.
Thanks in advance.
Cheers
Paul
On Sat, 4 Jan 2020, 21:14 Kevin Boyd, wrote:
> Hi,
>
> Can
Hi,
Can you share more information? Please upload your starting configuration
and a log file.
On Fri, Jan 3, 2020 at 10:29 AM Namit Chaudhary
wrote:
> Hi,
>
> Sorry. I didn't realize that attachments aren't uploaded. Below is a link
> for the files mentioned in the original mail.
>
>
Hi,
A few things besides any Ryzen-specific issues. First, your pinoffset for
the second one should be 16, not 17. The way yours is set up, you're
running on cores 0-15, then Gromacs will detect that your second
simulation parameters are invalid (because from cores 17-32, core 32 does
not exist)
Thank you for such a detailed response. The explanation was very helpful.
On Sat, Jan 4, 2020 at 10:00 PM Kenny Goossens
wrote:
> Hi Shakkira,
>
> In each of the consecutice iterations of the GROMOS force field, a
> reparameterization of the constants was performed in order to reproduce
>
Dear Proffesor Lemkul,
I have given below the MD RMSD for complex, and noted that Ligand is
getting detached again. When I viewed the trajectory on VMD it was
confirmed. The ligand did not abruptly got dislodged instead it slowly
came out of binding pocket and started moving around after.
Hello again,
I got notified that there is an issue for the first link, it needs to be
without the final dot:
http://manual.gromacs.org/2020/release-notes/index.html
Sorry for the inconvenience and happy new year!
Cheers
Paul
On 01/01/2020 18:11, Paul bauer wrote:
Hello GROMACS users!
On 1/4/20 1:38 AM, Snehasis Chatterjee wrote:
Thank you Prof. Lemkul for your kind reply. In mdp file, I will set
comm_grps to "system". But in tc-grps, can I couple capsid with Ca2+ ions?
240 Ca2+ ions are non-covalently attached with the capsid and have
important role in maintaining capsid
Very informative and interesting. I was using 54a7 forcefield with GROMACS
2018.4. I was confused with mdp parameters. Which version of GROMACS should
I use if I want to employ 54a7 force field?
On Sat, 4 Jan 2020, 22:00 Kenny Goossens,
wrote:
> Hi Shakkira,
>
> In each of the consecutice
On 1/4/20 11:29 AM, Kenny Goossens wrote:
Hi Shakkira,
In each of the consecutice iterations of the GROMOS force field, a
reparameterization of the constants was performed in order to reproduce
experimental data for various molecules (in the case of the GROMOS suite,
parameterization is
Hi Shakkira,
In each of the consecutice iterations of the GROMOS force field, a
reparameterization of the constants was performed in order to reproduce
experimental data for various molecules (in the case of the GROMOS suite,
parameterization is mainly fitted to free enthalpy of solvation).
Hi all
Can anyone explain the different code seen in forcefields of GROMOS like
53A6, 54A7, 43a1,. what does these numbers mean?
--
*Best Regards*
Shakkira E
PhD student INSPIRE Scholar
Department of Chemistry
sdmdlab.xyz
IIT Patna
Bihta
Patna 801106
--
Gromacs Users mailing list
* Please
Dear gromacs users,
I am tryingto make a shear flow in an electrolyte by moving two parallel
bilayers immersedin the electrolyte in opposite directions. I use the following
pull code (wherethe groups low and up are the two moving bilayers):
pull = yespull-coord1-type =
12 matches