Hi everyone,
I want to visualize how the dipole moment vectors of waters are aligned
around certain polar solutes. Can I select the waters to an index file and
give that to gmx dipoles to calculate dipole moment components of waters
and thus calculate the individual dipole moment vector of each
Hi all,
I have to carry out MD simulations involving PEG 6000 molecules. When I
first build this it is a very long (~480 Angstrom) linear chain. I have the
bond/angle/dihedral parameters for this linear structure. Usually when I
introduce a non-standard residue, I perform an optimization in
Hi,
groups can be specified using
gmx select
http://biophysics.med.jhmi.edu/~yliu120/tutorials.html
and
gmx make_ndx
http://bioinf.modares.ac.ir/workshop/md_sep_03_2012/fwspidr_tutor.pdf
HTH
Sajeewa
On Sat, May 6, 2017 at 6:35 AM, Felix Y Yang wrote:
> Thanks for the
dimension is not big enough. I will have to equilibrate the system in a
bigger box with a larger y dimension and run the umbrella sampling.
Thank you very much for your time.
Best,
Sajeewa
On Wed, Mar 29, 2017 at 11:26 PM, Sajeewa Pemasinghe <sajeew...@gmail.com>
wrote:
> So if t
So if the actual distance is 2.3 nm why does GROMACS measure it as 3.58
nm ?
On Wed, Mar 29, 2017 at 11:11 PM, Sajeewa Pemasinghe <sajeew...@gmail.com>
wrote:
> The coordinates of group1 center of mass are 44.466, 23.909,35.035 and
> that of group 2 are 67.467,23.994,34.088 a
The coordinates of group1 center of mass are 44.466, 23.909,35.035 and that
of group 2 are 67.467,23.994,34.088 as calculated in VMD . So the distance
is 23 A .
On Wed, Mar 29, 2017 at 11:05 PM, Sajeewa Pemasinghe <sajeew...@gmail.com>
wrote:
> Hi Justin,
>
> Thank you for the
Hi Justin,
Thank you for the prompt reply. I asked a second question correcting the
value of 23.0 nm. The distance value is 2.3 nm.
On Wed, Mar 29, 2017 at 10:57 PM, Justin Lemkul <jalem...@vt.edu> wrote:
>
>
> On 3/29/17 2:55 PM, Sajeewa Pemasinghe wrote:
>
>> Hi ev
Hi everyone,
I have run an equilibration of two linear molecules in a water box with
dimensions 117A x 54A x 70A for 150 ns. I am using the equilibrated
structures (not the final structure) in the final nanoseconds as starting
structures for an umbrella sampling calculation. The problem is that
Hi everyone,
I have run an equilibration of two linear molecules in a water box with
dimensions 117A x 54A x 70A for 150 ns. I am using the equilibrated
structures (not the final structure) in the final nanoseconds as starting
structures for an umbrella sampling calculation. The problem is that
Hi,
When I get a region sparsely populated like that, I increase the number of
points in that particular region and increase the k value to about 3000 but
not more than that. Increasing the k value to something like 2 will
result in the distribution getting very narrow and therefore further
Thank you very much. I really appreciate your help.
On Sun, Mar 26, 2017 at 6:16 PM, Justin Lemkul <jalem...@vt.edu> wrote:
>
>
> On 3/24/17 1:54 PM, Sajeewa Pemasinghe wrote:
>
>> Hi,
>>
>> I have two molecules which are not moving in the z axis due to bei
Thank you very much. I really appreciate it.
On Sun, Mar 26, 2017 at 6:17 PM, Justin Lemkul <jalem...@vt.edu> wrote:
>
>
> On 3/26/17 8:11 AM, Sajeewa Pemasinghe wrote:
>
>> Hi all,
>>
>> I have a system in which I need to maintain the center of mass distan
Hi all,
I have a system in which I need to maintain the center of mass distance
between two molecules constant for an umbrella window. The structures are
not strictly aligned along an axis as they are the product of an
equilibrium simulation.I have the following code.
pull = umbrella
Hi,
I have two molecules which are not moving in the z axis due to being
continuous across the periodic boxes. I want to keep the distance between
them fixed by pulling along x and y axes. So as I am pulling along x and y
axes does my ncoords = 2 ? By going along with this logic as long as my
Thank you very much for the information.
On Wed, Jan 18, 2017 at 11:27 PM, Justin Lemkul <jalem...@vt.edu> wrote:
>
>
> On 1/18/17 2:22 PM, Sajeewa Pemasinghe wrote:
>
>> So it should be monoatomic? Because this ion is a complex ion which has 19
>> atoms. So there w
1/18/17 3:04 AM, Sajeewa Pemasinghe wrote:
>
>> Hi all,
>>
>> I have an itp file to a new residue MGH. It is an ion with a (+2) charge.
>> I
>> have included the itp file in the topology file using #include MGH.itp. My
>> question is, will I be able to use thi
Hi all,
I have an itp file to a new residue MGH. It is an ion with a (+2) charge. I
have included the itp file in the topology file using #include MGH.itp. My
question is, will I be able to use this MGH ion to neutralize my system
using "gmx genion" without any further modifications to the
Dear all,
I have made mistake. I didn't compare the value of free energy at the
minimum with the plateau value. At all three bin numbers the difference is
close to 2 kCal mol-1.
So this is solved.
Best regards
Sajeewa
On Mon, Dec 19, 2016 at 1:15 PM, Sajeewa Pemasinghe <sajeew...@gmail.
Dear all,
I am calculating the PMF as the COM distance of two molecules are changing
using umbrella sampling ( pull = umbrella ). Each umbrella sampling
simulation runs for 50ns. When I calculate the PMF with default (200 bins)
settings using gmx wham I get the minimum in free energy of -1.19
Hi Ashan,
This (from the manual, section 4.3.5)
https://dl.dropboxusercontent.com/u/50317782/distance_restraints_gromacs.png
or this http://www.gromacs.org/Documentation/How-tos/Distance_Restraints
will help.
Best,
Sajeewa
On Thu, Dec 8, 2016 at 5:35 AM, ashan dayananda
20 matches
Mail list logo