Dear All,
I am reading up about the tabulation table. I was wondering, how does GROMACS
deal with periodic structure when the table is tabulated since PME still not
available in my version? Also is the new version of GROMACS can do user-PME?
Thank you very much.
Best regards,
Ben
--
Gromacs
ory Center for Molecular
Biophysics
From: gromacs.org_gmx-users-boun...@maillist.sys.kth.se
on behalf of Tam, Benjamin
Sent: Monday, August 12, 2019 7:38:51 AM
To: gromacs.org_gmx-users@maillist.sys.kth.se
Subject: [EXTERNAL] [gmx-users] Turning off electrostat
Dear All,
I am thinking of a way to simulate a porous system where the gases are very
diluted. I would like to add more molecules into the system in order to
increase the statistic but would like to turn off molecules - molecules
electrostatic interaction. I understand there are ways to turn
I’ll also ask, do you actually need a barostat, or will
NVT be fine? Or are there ways to relax your system to an appropriate density
without seeing the problem behavior?
Best,
Jacob
On May 23, 2019, at 10:23 AM, Tam, Benjamin
mailto:benjamin.tam...@ucl.ac.uk>> wrote:
Dear all,
T
of bug in the newer version or am I missing something?
Best,
Ben
-Original Message-
From: gromacs.org_gmx-users-boun...@maillist.sys.kth.se
On Behalf Of Tam, Benjamin
Sent: 23 May 2019 11:40
To: gromacs.org_gmx-users@maillist.sys.kth.se
Subject: [gmx-users] Pressure coupling problem
Dear
Dear Gromacs user,
Currently, I am baffled about a simulation that I am running and I hope I will
find some answer here.
Initially, I have run my system with Berendsen barostat to equilibrate for 1
ns. The system looks fine as there is no box explosion.
However, after the equilibration, I
Dear gromacs user,
For the improper dihedral function type 4, when writing in [ dihedraltypes ],
which position in the naming is the central atoms? Thank you very much.
Best regards,
Ben
--
Gromacs Users mailing list
* Please search the archive at
Dear Gromacs-User,
I have a question regarding graphene wall piston simulation. As far as I
understand, a constant acceleration/force is applied onto the graphene wall at
x direction when I put acceleration = 0.1 0.0 0.0 . However when I look at the
movie, it seems to have sudden jerk movement
Hi Justin,
Thank you for replying, the problem is this:
Fatal error:
Atomtype Zr110418 not found
For more information and tips for troubleshooting, please check the GROMACS
website at http://www.gromacs.org/Documentation/Errors
because the number and the name combine together i.e. supposed to
Dear gromacs user,
I am trying to simulate a large system, but I ran into some fundamental
problems. For example in the .gro file, the name of the atoms merge with the
number count:
2MOL C2 9998 3.987 2.259 6.276
2MOL C5 3.987 2.061 6.079
2MOL C11
10 matches
Mail list logo