I see. Now I understand what "pull-start" option means. Changing that
option made it work! Thank you Justin.
On Mon, Aug 8, 2016 at 6:04 AM, Justin Lemkul wrote:
>
>
> On 8/7/16 1:21 PM, Dan Gil wrote:
>
>> In Gromacs/4.6, I used init to define the distance from the solvent COM
On 8/7/16 1:21 PM, Dan Gil wrote:
In Gromacs/4.6, I used init to define the distance from the solvent COM
that the solute should be pulled to. Has it changed for Gromacs/5.1?
Nothing has changed except (1) syntax and (2) the ability to now apply multiple
restraints simultaneously.
In Gromacs/4.6, I used init to define the distance from the solvent COM
that the solute should be pulled to. Has it changed for Gromacs/5.1?
What should I do if I want to pull the solute to [0, 1, 2, 3] nm away from
the solvent COM?
Here is the section I think you are talking about also:
Pull
On 8/7/16 1:13 PM, Dan Gil wrote:
Hi,
I've made the change you suggested. The output file pullx.xvg has changed
from something like:
@ s0 legend "1"
@ s1 legend "1 dZ"
0. 3.01072 3.01072
0.2000 2.98101 2.98101
0.4000 2.94186 2.94186
0.6000 2.95316 2.95316
to this:
@ s0 legend "1"
@ s1
Hi,
I've made the change you suggested. The output file pullx.xvg has changed
from something like:
@ s0 legend "1"
@ s1 legend "1 dZ"
0. 3.01072 3.01072
0.2000 2.98101 2.98101
0.4000 2.94186 2.94186
0.6000 2.95316 2.95316
to this:
@ s0 legend "1"
@ s1 legend "1 dZ"
0. 3.01072 -3.01072
On 8/7/16 11:35 AM, Dan Gil wrote:
Hi,
The pullx.xvg file is returning the coordinates of the solvent, and not the
solute (a_Cooh) as I want.
The solute is being pulled in a coordinate other than Z, although I specify:
pull-coord1-dim =N N Y
What is going on here?
Swap
pull-coord1-groups
Hi,
The pullx.xvg file is returning the coordinates of the solvent, and not the
solute (a_Cooh) as I want.
The solute is being pulled in a coordinate other than Z, although I specify:
pull-coord1-dim =N N Y
What is going on here?
On Sun, Aug 7, 2016 at 7:20 AM, Billy Williams-Noonan <
Hi All,
I'm having a similar problem and wouldn't mind some advice either. I am
getting LINCS warnings on one cluster that I run my sampling on, but the
pull-code works fine on other clusters we have access to, which is making
me doubt the entire process.
Best regards,
Billy
On 7 August 2016
Hi,
I am changing from Gromacs/4.6 to Gromacs/5.1, and I have a piece of .mdp
file that I am confused with.
I am pulling an atom of solute, indexed a_Cooh, towards the COM of solvent.
This is a slab geometry, with the plane normal to the z-axis direction. My
output (pullx.xvg) should contain the