Re: [HCP-Users] Melodic ICA idle

2018-03-19 Thread Will Khan
Dear HCP members/Users, Thanks so much for your prompt advice and suggestions! Steve, if I were to perform ICA on the grayordinates would I still be able to dualregress this onto a patient nifti dataset? Like others have suggested, wouldn't my patient data need to be in cifti? Cheers :) Will

Re: [HCP-Users] Fw:

2018-03-19 Thread Timothy Coalson
NOTE: this assumes your volumes are in fact aligned via coordinates already (you can check for this by loading the ROI and an SBRef or similar image that is known to align with the rfMRI). wb_command -volume-affine-resample mask.nii.gz identity.txt rfMRI.nii.gz TRILINEAR resampled_mask.nii.gz

Re: [HCP-Users] Fw:

2018-03-19 Thread HERACLES PANAGIOTIDES
Thank you very much, Tim, for the help. I think I ‘d like to try the wb_command -volume-affine-resample approach. Could you please help me with a complete command given a “mask.nii.gz” that needs to be transformed into a “rfMRI.nii.gz” space. Thanks, -Heracles From: Timothy Coalson

Re: [HCP-Users] Fw:

2018-03-19 Thread Timothy Coalson
FSL's resampling does not truly respect the coordinates specified by the nifti headers, which makes an FSL solution more complicated. FSLview also doesn't respect those coordinates, and I am unsure whether its "alignment" is the same as its resampling uses, or whether it is incorrect in a