I am out of the office until 12/31/2012.
I am retiring as of 3/31/2011, but will not be available after 3/25/2011.
If you need technical assistance for Serivce Test, please contact Robin
Hauptman, Karen Pettorossi, or Kirill Barannikov. If you need technical
assistance for Consolidated Service
With memory limits we have to remember that supports is different from
performs well up to. As my audiences will know I talk about the work
z/OS and Hardware Development did to make memory scale well.
Martin
Martin Packer,
Mainframe Performance Consultant, zChampion
Worldwide Banking Center of
I have a very nagging problem where I cannot run a java program on
z/OS-USS that is attempting to use the network interface (UPD PORT
514) to write to the SYSLOG daemon. The following is the message I
am getting:
java.net.BindException: EDC5111I Permission denied.
Talking to IBM they say this
On 3/26/2011 7:00 AM, Donald Likens wrote:
I have a very nagging problem where I cannot run a java program on
z/OS-USS that is attempting to use the network interface (UPD PORT
514) to write to the SYSLOG daemon. The following is the message I
am getting:
java.net.BindException: EDC5111I
I have a very nagging problem where I cannot run a java program on
z/OS-USS that is
attempting to use the network interface (UPD PORT
514) to write to the SYSLOG daemon. The following is the message I am
getting:
java.net.BindException: EDC5111I Permission denied.
Talking to IBM they say
We simply created an ISPF profile dataset (SYS2.ISPF.PROF) that was
copied into the new user ISPF profile PDS the first time the new user
logged on.
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email
Double oorah as FLOWASM is extensively used as well :-)
Rob Scott
Lead Developer
Rocket Software
275 Grove Street * Newton, MA 02466-2272 * USA
Tel: +1.617.614.2305
Email: rsc...@rs.com
Web: www.rocketsoftware.com
-Original Message-
From: IBM Mainframe Discussion List
The most recent post of Don Higgins is in some ways a very sensible and useful
one; in some other ways it is less so.
An irrational number is one that is NOT expressible as the quotient of two
integers, and the number 1/3 is thus a rational, unambiguously so.
The diffficulties that arise
The error says it all ...it is a bind problem.
It is for a sub-1024 port so you need additional sign.. I would check the
port statements as well... in either case it isn't a permission bit issue.
Rob Schramm
On Mar 26, 2011 9:09 AM, Lizette Koehler stars...@mindspring.com wrote:
I have a very
On Sat, 26 Mar 2011 13:47:27 +, john gilmore wrote:
... A rational that has a terminating decimal expansion may have a
non-terminating hexadecimal expansion and vice versa.
Not vice versa. Any number that has a terminating hexadecimal expansion
has also a terminating decimal expansion.
http://publib.boulder.ibm.com/infocenter/wpdoc/v6r0/index.jsp?topic=/com.ibm.wp.zos.rn.doc/release_notes/release_notes.html
Problem: SOAPException during base portal configuration on z/OS
When running job EJPSBCA for configuring a base portal into a
WebSphere base application server node, or jobs
On 3/24/2011 1:19 PM, Clark Morris wrote:
On 19 Mar 2011 06:55:11 -0700, in bit.listserv.ibm-main you wrote:
So (once again) the tech support bods (vendor and customer) are dancing
around on egg-shells trying to accommodate policy decisions made by
sales/marketing/legal droids.
I consider the
I'm getting a feeling of Deja Vu on this. Didn't we discuss this last
week? Perhaps on a different forum. To bind to the syslogd port, UDP
port 514, you likely need to be either UID(0) or have the job name in
the TCPIP parms as authorized. This assumes RESTRICTLOWERPORTS is active
in your TCPIP
In
77142d37c0c3c34da0d7b1da7d7ca3430882b...@nwt-s-mbx2.rocketsoftware.com,
on 03/24/2011
at 06:30 PM, Bill Fairchild bi...@mainstar.com said:
I keep trying all these links that are posted and I keep seeing a
PoOps whose -x level is never any higher than -8. Shmuel is asking
for a -9.
My
In 00e601cbea4a$35625f70$a0271e50$@hawkins1...@sbcglobal.net, on
03/24/2011
at 10:37 AM, Ron Hawkins ron.hawkins1...@sbcglobal.net said:
Otherwise AFAIK DFSORT will have pages stolen and demand page with or
without block paging just like any other batch job.
I never said otherwise.
I'm sure
In 4d8bb1eb.6000...@dino-software.com, on 03/24/2011
at 02:04 PM, Dave Roeser dave.roe...@dino-software.com said:
Anyway, he wishes to know if this is an in-storage sort or is it to
use external media?
What's the working set? If the data are larger than the working set
then he will see
Anyone running DITTO/ESA for MVS Release 3 - PTF level: INAFLV2 under
z/OS 1.12? I keep receiving message No access authority under the DB -
Disk Browse utility. We have the RACF Facility Class DITTO profiles
defined. But we are still getting the error. Any ideas?
Richard Pinion pisze:
Anyone running DITTO/ESA for MVS Release 3 - PTF level: INAFLV2 under
z/OS 1.12? I keep receiving message No access authority under the DB -
Disk Browse utility. We have the RACF Facility Class DITTO profiles
defined. But we are still getting the error. Any ideas?
Ditto is running authorized.
Here is the RACF info.
DITTO.DISK.FULLPACK.* (G)
DITTO.DISK.* (G)
DITTO.OAM.* (G)
DITTO.OTHER.ALL.* (G)
DITTO.TAPE.* (G)
DITTO.VSAM.* (G)
CLASS NAME
-
Hi John,
Did you price SAS for your PCnot so expensiveand then MXG runs there
as well.
Ron H. has done this forever...at least since 1998.
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of McKown, John
I know that MXG can do this. We can't run MXG. We
Well, in theory you should have access. :-(
Try to use DITTO.FUNCTION.DB profile or create DITTO.** and temporarily
delete all other DITTO profiles. Another idea is to check DASDVOL profiles.
HTH
--
Radoslaw Skorupka
Lodz, Poland
--
BRE Bank SA
ul. Senatorska 18
00-950 Warszawa
Shmuel,
Google for PGSER, then read my message again. My point was that using
data spaces does not automatically mean demand paging, and I was
asking what DFSORT does or doesn't do to manage its data spaces.
I'd guess that they are using DSPSERV to load dataspace pages and avoid
serial
What I have learned in the last few minutes is that data sets that do not have
EXTENDED REQUIRED in their SMS Data Class work. So at least I know the
security is working.
Thanks for your suggestions! Isn't it late in Poland?
Richard, Vickie, and Randy Pinion
---
Richard Pinion pisze:
What I have learned in the last few minutes is that data sets that do not have
EXTENDED REQUIRED in their SMS Data Class work. So at least I know the
security is working.
I believe the difference is between regular PS (maybe others) and
Extended Format PS datasets.
Just checked - I have no problem with browsing PS-E dataset with DITTO.
It was checked on sandbox system where I have all the authorities.
--
Radoslaw Skorupka
Lodz, Poland
--
BRE Bank SA
ul. Senatorska 18
00-950 Warszawa
www.brebank.pl
Sąd Rejonowy dla m. st. Warszawy
XII Wydział
Hi,
I would think that setdef asid would make that the psaaold asid
However I try that command it doesn't seem to work out that way
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to
It was 15% used of 6 Mod 3 paging packs, 9 Mod 9 sort work volumes.
On Sat, Mar 26, 2011 at 7:23 PM, Shmuel Metz (Seymour J.)
shmuel+ibm-m...@patriot.net wrote:
In 4d8bb1eb.6000...@dino-software.com, on 03/24/2011
at 02:04 PM, Dave Roeser dave.roe...@dino-software.com said:
Anyway, he wishes
Plus if you use something like co:z ... you could run sas on the pc using
datasets on zos
Rob
On Mar 26, 2011 9:40 PM, Bruce Hewson bruce_hew...@hotmail.com wrote:
Hi John,
Did you price SAS for your PCnot so expensiveand then MXG runs
there
as well.
Ron H. has done this
28 matches